218 344

Cited 0 times in

동적 외고정 장치를 이용한 수지 근위지절관절 강직의 치료

Other Titles
 Hinged Device for Stiffness of Proximal Interphalangeal Joint of Finger 
Authors
 강호정  ;  강기원  ;  강응식 
Citation
 Journal of the Korean Society for Surgery of the Hand (대한수부외과학회지), Vol.2(2) : 349-355, 1997 
Journal Title
Journal of the Korean Society for Surgery of the Hand(대한수부외과학회지)
ISSN
 1598-3889 
Issue Date
1997
Keywords
proximal interphalangeal joint, stiffness, hinged device
Abstract
The proximal interphalangeal joint of finger is important structure in hand function and injury to this joint may result in stiffness, chronic instabilitiy and degenerative arthritis, especially if it is recognized later or treated improperly. The Compass PIP(proximal interphalangeal joint) Hinge is a dynamic external fixator that allows protected proximal interphalangeal mobilization after closed reduction, open reduction and internal fixation, volar plate arthroplasty, or other salvage procedures. It is important to get the congruence of articular surface and singular point that is the center of axis of the proximal interphalangeal joint for good result. We report two cases which show satisfactory result using this device. The first case was 23 year-old male who complains of limitation of motion of the proximal interphalangeal(PIP) joint of right index finger. He got hyperextension injury of PIP joint about 3 months ago and

found that there was avulsion fracture of proximal phalanx base of index finger. He was treated open reduction and internal fixation and immobilized for 4 weeks and received physiotherapy after that period. Initial range of motion of PIP joint was flexion 20¡Æ, extension 0¡Æ. Six month after arthrolysis and PIP hinge external fixation, flexion and extension was improved to 100¡Æ, 0¡Æ respectively. The second case was 25 year-old male who visited to our hospital due to nonunion of middle phalax of right index finger after crushing injury. He received internal fixation and autoiliac bone graft. After 3 month, union was gained but stiffnes of PIP joint was remained. Initial range of motion of PIP joint was flexion 10¡Æ, extension 0¡Æ. One year after arthrolysis and PIP hinged device operation, the range of motion was improved to flexion 90¡Æ, extension -10¡Æ.
Files in This Item:
T199702801.pdf Download
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Orthopedic Surgery (정형외과학교실) > 1. Journal Papers
Yonsei Authors
Kang, Ho Jung(강호정) ORCID logo https://orcid.org/0000-0003-0273-1264
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/177707
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links