Cited 0 times in
T2 Relaxographic Mapping using 8-echo CPMG MRI Pulse Sequence
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 서진석 | - |
dc.date.accessioned | 2020-07-03T17:12:25Z | - |
dc.date.available | 2020-07-03T17:12:25Z | - |
dc.date.issued | 1997 | - |
dc.identifier.issn | 1226-9751 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/177346 | - |
dc.description.abstract | The mapping of the spin-spin relaxation time T2 in pixed-by-pixel was suggested as a quantitative diagnostic tool in medicine. Although the CPMG pulse sequence has been known to be the best pulse sequence for T2 measurement in physics NMR, the supplied pulse sequence by the manufacture of MRI system was able to obtain the maximum of 4 CPMG images. Eight or more images with different echo time TEs are required to construct a reliable T2 map, so that two or more acquisitions were required, which easily took more than 10 minutes. 4-echo CPMG imaging pulse sequence was modified to generate the maximum of 8 MR images with evenly spaced echo time TEs. In human MR imaging, since patients tend to move at least several pixels between the different acquisitions, 8-echo CPMG imaging sequence reduces the acquisition time and may remove any misregistration of each pixel's signal for the fitting T2. The resultant T2 maps using the theoretically simulated images and using the MR images of the human brain suggested that 8 echo CPMG sequence with short echo spacing such as 17∼20 msec can give the reliable T2 map. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | Korean | - |
dc.publisher | 대한자기공명의과학회 | - |
dc.relation.isPartOf | Journal of the Korean Society of Magnetic Resonance in Medicine (대한자기공명의과학회지) | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | T2 Relaxographic Mapping using 8-echo CPMG MRI Pulse Sequence | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Radiology (영상의학교실) | - |
dc.contributor.googleauthor | E-K. Jeong | - |
dc.contributor.googleauthor | S-H. Lee | - |
dc.contributor.googleauthor | J-S. Suh | - |
dc.contributor.googleauthor | Y-Y wak | - |
dc.contributor.googleauthor | S-A. Shin | - |
dc.contributor.googleauthor | Y-K. Kwon | - |
dc.contributor.googleauthor | Y. Huh | - |
dc.contributor.localId | A01916 | - |
dc.relation.journalcode | J01880 | - |
dc.identifier.eissn | 2288-3800 | - |
dc.contributor.alternativeName | Suh, Jin Suck | - |
dc.contributor.affiliatedAuthor | 서진석 | - |
dc.citation.volume | 1 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 6 | - |
dc.citation.endPage | 15 | - |
dc.identifier.bibliographicCitation | Journal of the Korean Society of Magnetic Resonance in Medicine (대한자기공명의과학회지), Vol.1(1) : 6-15, 1997 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.