135 396

Cited 0 times in

T1 강조 자기공명영상에서 고신호강도를 보이는 국소 간결절 : 다중시기 조영증강 역동자기공명영상에서 정량적 분석을 통한 소간세포암과 이형성결절의 감별

DC Field Value Language
dc.contributor.author김기황-
dc.contributor.author유정식-
dc.contributor.author이광훈-
dc.date.accessioned2020-01-23T05:32:48Z-
dc.date.available2020-01-23T05:32:48Z-
dc.date.issued1999-
dc.identifier.issn0301-2867-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/174367-
dc.description.abstractPURPOSE: To evaluate the usefulness of quantitative analysis of the degree of enhancement in dynamic MRimaging used to differentiate dysplastic nodule (DN) from small hepatocellular carcinoma (HCC), both of which showhigh signal intensity on T1-weighted images. MATERIALS AND METHODS: From 26 small HCCs and 71 DNs, all of whichshowed homogeneous high signal intensity on T1-weighted images among 42 patients with liver cirrhosis, weselected 16 small HCCs and 10 DNs of more than 1cm in diameter which were diagnosed by biopsy and follow-up imaging. Dynamic MR imaging of the entire liver was obtained using the breath-hold technique at postinjection 10sec. (phase 1), 35 sec. (phase 2), 60 sec. (phase 3), and 5 min. (delayed) after intravenous manual injection ofGd-DTPA (0.1 mmol/kg) at a velocity of 3-4 cc/sec. Nodule-to-liver contrast-to-noise ratios (CNR) during eachphase were calculated by measurement of the region of interest. RESULTS: On precontrast T1-weighted images, themean CNR of small HCCs was 2.873, and that of DNs was 3.854, there was thus no significant statistical difference(p>0.01). On postcontrast images, the CNR of small HCCs during each phase was 5.565, 3.790, 1.704, and 1.282, withpeak CNR phase 1 and a mostly decreasing trend thereafter. However, the CNR of DNs during each phase was 3.053,1.561, 0.919, and 1.038 ; there was thus showed no significant increase during phase 1 in comparison with the CNRsseen on precontrast images. During the precontrast stage and phase 1, the average difference in CNR was 2.691 forsmall HCCs and 0.801 for DNs the difference was thus significant (p<0.01). CONCLUSION: Quantitative analysis ofCNR, reflecting the degree of nodule-to-liver enhancement in dynamic MR imaging, was found to be useful for thedifferentiation of small HCCs from DNs, both of which show high signal intensity on T1-weighted images.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한방사선의학회-
dc.relation.isPartOfJournal of the Korean Radiologist Society (대한방사선의학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleT1 강조 자기공명영상에서 고신호강도를 보이는 국소 간결절 : 다중시기 조영증강 역동자기공명영상에서 정량적 분석을 통한 소간세포암과 이형성결절의 감별-
dc.title.alternativeFocal Hepatic Nodules with High Signal Intensity on T1-weighted MR Imaging: Differentiation of Small Hepatocellular Carcinoma from Dysplastic Nodule by Quantitative Analysis of Multi-phase Contrast-enhanced DynamicMR Imaging-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학교실)-
dc.contributor.googleauthor이광훈-
dc.contributor.googleauthor유정식-
dc.contributor.googleauthor김기황-
dc.contributor.googleauthor조나리야-
dc.contributor.googleauthor정미경-
dc.contributor.googleauthor김재근-
dc.contributor.localIdA00345-
dc.contributor.localIdA02500-
dc.contributor.localIdA02676-
dc.relation.journalcodeJ01844-
dc.subject.keywordLiver neoplasms-
dc.subject.keywordLiver, MR-
dc.contributor.alternativeNameKim, Ki Whang-
dc.contributor.affiliatedAuthor김기황-
dc.contributor.affiliatedAuthor유정식-
dc.contributor.affiliatedAuthor이광훈-
dc.citation.volume40-
dc.citation.number6-
dc.citation.startPage1153-
dc.citation.endPage1158-
dc.identifier.bibliographicCitationJournal of the Korean Radiologist Society (대한방사선의학회지), Vol.40(6) : 1153-1158, 1999-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.