Design and Implementation of a New Wireless Carotid Neckband Doppler System with Wearable Ultrasound Sensors: Preliminary Results

Authors
 Ilseob Song  ;  Jongmin Yoon  ;  Jinbum Kang  ;  Min Kim  ;  Won Seuk Jang  ;  Na-Young Shin  ;  Yangmo Yoo 
Citation
 Applied Sciences, Vol.9(11) : e2202, 2019 
Journal Title
APPLIED SCIENCES-BASEL
Issue Date
2019
Keywords
carotid ultrasonography ; neckband ; wearable ultrasound ; point-of-care
Abstract
Noninvasive monitoring of blood flow in the carotid artery is important for evaluating not only cerebrovascular but also cardiovascular diseases. In this paper, a wireless neckband ultrasound Doppler system, in which two 2.5-MHz ultrasonic sensors are utilized for acquiring Doppler signals from both carotid arteries, is presented for continuously evaluating blood flow dynamics. In the developed wireless neckband Doppler system, the acquired Doppler signals are quantized by 14-bit analog-to-digital-converters running at 40 MHz, and pre-processing operations (i.e., demodulation and clutter filtering) are performed in an embedded field programmable gate array chip. Then, these data are transferred to an external smartphone (i.e., Galaxy S7, Samsung Electronics Co., Suwon, Korea) via Bluetooth 2.0. Post-processing (i.e., Fourier transform and image processing) is performed using an embedded application processor in the smartphone. The developed carotid neckband Doppler system was evaluated with phantom and in vivo studies. In a phantom study, the neckband Doppler system showed comparable results with a commercial ultrasound machine in terms of peak systolicvelocityandresistiveindex,i.e.,131.49±3.97and0.75±0.02vs. 131.89±2.06and0.74±0.02, respectively. Inaddition,inthein vivostudy,theneckbandDopplersystemsuccessfullydemonstrated its capability to continuously evaluate hemodynamics in both common carotid arteries. These results indicatethatthedevelopedwirelessneckbandDopplersystemcanbeusedforcontinuousmonitoring of blood flow dynamics in the common carotid arteries in point-of-care settings.
Files in This Item:
T201903869.pdf Download
DOI
10.3390/app9112202
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Medical Engineering (의학공학교실) > 1. Journal Papers
Yonsei Authors
Chang, Won Seok(장원석) ORCID logo https://orcid.org/0000-0002-4925-3549
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/173074
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links