685 695

Cited 18 times in

Design and Implementation of a New Wireless Carotid Neckband Doppler System with Wearable Ultrasound Sensors: Preliminary Results

DC Field Value Language
dc.contributor.author장원석-
dc.date.accessioned2019-12-18T00:29:31Z-
dc.date.available2019-12-18T00:29:31Z-
dc.date.issued2019-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/173074-
dc.description.abstractNoninvasive monitoring of blood flow in the carotid artery is important for evaluating not only cerebrovascular but also cardiovascular diseases. In this paper, a wireless neckband ultrasound Doppler system, in which two 2.5-MHz ultrasonic sensors are utilized for acquiring Doppler signals from both carotid arteries, is presented for continuously evaluating blood flow dynamics. In the developed wireless neckband Doppler system, the acquired Doppler signals are quantized by 14-bit analog-to-digital-converters running at 40 MHz, and pre-processing operations (i.e., demodulation and clutter filtering) are performed in an embedded field programmable gate array chip. Then, these data are transferred to an external smartphone (i.e., Galaxy S7, Samsung Electronics Co., Suwon, Korea) via Bluetooth 2.0. Post-processing (i.e., Fourier transform and image processing) is performed using an embedded application processor in the smartphone. The developed carotid neckband Doppler system was evaluated with phantom and in vivo studies. In a phantom study, the neckband Doppler system showed comparable results with a commercial ultrasound machine in terms of peak systolicvelocityandresistiveindex,i.e.,131.49±3.97and0.75±0.02vs. 131.89±2.06and0.74±0.02, respectively. Inaddition,inthein vivostudy,theneckbandDopplersystemsuccessfullydemonstrated its capability to continuously evaluate hemodynamics in both common carotid arteries. These results indicatethatthedevelopedwirelessneckbandDopplersystemcanbeusedforcontinuousmonitoring of blood flow dynamics in the common carotid arteries in point-of-care settings.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageEnglish-
dc.publisherMDPI AG-
dc.relation.isPartOfApplied Sciences-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleDesign and Implementation of a New Wireless Carotid Neckband Doppler System with Wearable Ultrasound Sensors: Preliminary Results-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Medical Engineering (의학공학교실)-
dc.contributor.googleauthorIlseob Song-
dc.contributor.googleauthorJongmin Yoon-
dc.contributor.googleauthorJinbum Kang-
dc.contributor.googleauthorMin Kim-
dc.contributor.googleauthorWon Seuk Jang-
dc.contributor.googleauthorNa-Young Shin-
dc.contributor.googleauthorYangmo Yoo-
dc.identifier.doi10.3390/app9112202-
dc.contributor.localIdA04793-
dc.relation.journalcodeJ03706-
dc.identifier.eissn2076-3417-
dc.subject.keywordcarotid ultrasonography-
dc.subject.keywordneckband-
dc.subject.keywordwearable ultrasound-
dc.subject.keywordpoint-of-care-
dc.contributor.alternativeNameChang, Won Seok-
dc.contributor.affiliatedAuthor장원석-
dc.citation.volume9-
dc.citation.number11-
dc.citation.startPagee2202-
dc.identifier.bibliographicCitationApplied Sciences, Vol.9(11) : e2202, 2019-
dc.identifier.rimsid63356-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Medical Engineering (의학공학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.