dc.description.abstractPURPOSE: To evaluate the effect of variable scanning protocols of computed tomography for evaluation of pre-implant site of the mandible through the comparison of the reformatted cross-sectional images of helical CT scans obtained with various imaging parameters versus those of conventional CT scans. MATERIALS AND METHODS: A dry mandible was imaged using conventional nonoverlapped CT scans with 1 mm slice thickness and helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5, 2.0, 2.5 and 3.0. All helical images were reconstructed at reconstruction interval of 1 mm. DentaScan reformatted images were obtained to allow standardized visualization of cross-sectional images of the mandible. The reformatted images were reviewed and measured separately by 4 dental radiologists. The image qualities of continuity of cortical outline, trabecular bone structure and visibility of the mandibular canal were evaluated and the distance between anatomic structures were measured by 4 dental radiologists. RESULTS: On image qualities of continuity of cortical outline, trabecular bone structure and visibility of the mandibular canal and in horizontal measurement, there was no statistically significant difference among conventional and helical scans with pitches of 1.0, 1.5 and 2.0. In vertical measurement, there was no statistically significant difference among the conventional and all imaging parameters of helical CT scans with pitches of 1.0, 1.5, 2.0, 2.5 and 3.0. CONCLUSION: The images of helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5 and 2.0 are as good as those of conventional CT scans with 1 mm slice thickness for evaluation of pre-dental implant site of the mandible. Considering the radiation dose and patient comfort, helical CT scans with 1 mm slice thickness and pitch of 2.0 is recommended for evaluation of pre-implant site of the mandible.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한구강악안면방사선학회지-
dc.relation.isPartOf치과방사선-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title영상재구성 전산화 단층촬영에서 촬영조건의 변화가 하악골 술전 임플란트 부위 평가에 미치는 영향-
dc.title.alternativeEffect of variable scanning protocolson the pre-implant site evaluation of the mandiblein reformatted computed tomography-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Advanced General Dentistry (통합치의학과)-
dc.contributor.googleauthor김기덕-
dc.contributor.googleauthor박창서-
dc.contributor.localIdA00332-
dc.contributor.localIdA01715-
dc.relation.journalcodeJ03688-
dc.contributor.alternativeNameKim, Kee Deog-
dc.contributor.affiliatedAuthor김기덕-
dc.contributor.affiliatedAuthor박창서-
dc.citation.volume29-
dc.citation.number1-
dc.citation.startPage21-
dc.citation.endPage32-
dc.identifier.bibliographicCitation치과방사선, Vol.29(1) : 21-32, 1999-