Cited 4 times in
Development of a frequency-dependent-type apex locator with automatic compensation
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김덕원 | - |
dc.contributor.author | 이승종 | - |
dc.date.accessioned | 2019-11-11T05:06:25Z | - |
dc.date.available | 2019-11-11T05:06:25Z | - |
dc.date.issued | 2000 | - |
dc.identifier.issn | 0278-940X | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/171617 | - |
dc.description.abstract | Among apex locators, the frequency dependent type is more accurate and convenient to use than others. However, the accuracy of the apex locator is still influenced by the presence of various electrolytes used in root canal treatments. In this study, we developed a frequency-dependent electronic apex locator minimizing the influence of electrolytes on the measurement of root canal lengths. It was confirmed that the two frequencies of 0.5 and 10 kHz are better than the conventional ones of 0.4 and 8 kHz. The impedance ratio of the two different frequencies represents the position of the file in root canal, and the voltage difference of the two frequencies represents the status of the fluid in the root canal. As a result of compensation using the voltage differences of the two frequencies, the errors decreased significantly on average from +0.54 mm to +0.18 mm in H2O2 solution (p < 0.01), and from -0.33 mm to -0.01 mm in NaOCl solution (p < 0.01) in the tooth model experiments. | - |
dc.description.statementOfResponsibility | restriction | - |
dc.language | English | - |
dc.publisher | Begell House | - |
dc.relation.isPartOf | Critical Reviews in Biomedical Engineering | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.subject.MESH | Analysis of Variance | - |
dc.subject.MESH | Electric Impedance | - |
dc.subject.MESH | Electrolytes | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Odontometry/instrumentation | - |
dc.subject.MESH | Root Canal Irrigants | - |
dc.subject.MESH | Root Canal Preparation/instrumentation* | - |
dc.subject.MESH | Therapeutic Irrigation | - |
dc.subject.MESH | Tooth Apex/anatomy & histology* | - |
dc.title | Development of a frequency-dependent-type apex locator with automatic compensation | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Medical Engineering (의학공학교실) | - |
dc.contributor.googleauthor | Kim DW | - |
dc.contributor.googleauthor | Nam KC | - |
dc.contributor.googleauthor | Lee SJ | - |
dc.identifier.doi | 10.1615/CritRevBiomedEng.v28.i34.200 | - |
dc.contributor.localId | A00376 | - |
dc.contributor.localId | A02925 | - |
dc.relation.journalcode | J03680 | - |
dc.identifier.eissn | 1943-619X | - |
dc.identifier.pmid | 11108217 | - |
dc.identifier.url | http://www.dl.begellhouse.com/journals/4b27cbfc562e21b8,657c94ee3fd00c46,5e025323540eddbd.html | - |
dc.contributor.alternativeName | Kim, Deok Won | - |
dc.contributor.affiliatedAuthor | 김덕원 | - |
dc.contributor.affiliatedAuthor | 이승종 | - |
dc.citation.volume | 28 | - |
dc.citation.number | 3~4 | - |
dc.citation.startPage | 473 | - |
dc.citation.endPage | 479 | - |
dc.identifier.bibliographicCitation | Critical Reviews in Biomedical Engineering, Vol.28(3~4) : 473-479, 2000 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.