429 737

Cited 11 times in

Accuracy of Customized Prefabricated Screw-Type Immediate Provisional Restorations after Single-Implant Placement

Authors
 Kyung Chul Oh  ;  Jee-Hwan Kim  ;  Chang-Woo Woo  ;  Hong Seok Moon 
Citation
 JOURNAL OF CLINICAL MEDICINE, Vol.8(4) : E490, 2019 
Journal Title
JOURNAL OF CLINICAL MEDICINE
Issue Date
2019
Keywords
computer-aided design ; computer-assisted implant surgical guide ; digital workflow ; immediateprovisionalization ; prosthetic-driven implantplacement ; single-implant
Abstract
Limited evidence is available comparing the differences between pre-operative and post-operative 3D implant positions from the viewpoint of prosthetics. We aimed to investigate the differences between preplanned positions of virtualprovisionalrestorationsand their actual positions following fully guidedsingle-implantplacement. Ten maxillary typodonts with missing right central incisors were imaged using cone-beam computed tomography, and digital impressions were obtained using an intraoral scanner. These data were imported into implant-planning software, following which theprovisionalrestorationswere designed.Afterdata superimposition, an appropriate implant position was determined, and a computer-assisted implant surgical guide was designed for each typodont. Orders generated from the implant-planning software were imported into relevant computer-aided design software to design the custom abutments. The abutments,provisionalrestorations, and surgical guides were fabricated, and each restoration was cemented to the corresponding abutments, generating ascrew-typeimmediateprovisionalrestoration. The implants were placed using the surgical guides, and thescrew-typeprovisionalrestorationswere engaged to the implants. The typodonts were then rescanned using the intraoral scanner. Therestorationsdesigned at the treatment planning stage were compared with those in the post-operative scan using metrology software. The angular deviation around the central axis of the implant was measured, and the differences in the crown position were converted to root mean square (RMS) values. The post-operativeprovisionalrestorationsexhibited an absolute angular deviation of 6.94 ± 5.78° and an RMS value of 85.8 ± 20.2 µm when compared with their positions in the pre-operative stage. Within the limitations of the present in vitro study, the results highlight the potential application ofcustomizedprefabricatedimmediateprovisionalrestorationsaftersingle-implantplacement.
Files in This Item:
T201902317.pdf Download
DOI
10.3390/jcm8040490
Appears in Collections:
6. Others (기타) > Severance Hospital (세브란스병원) > 1. Journal Papers
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Jee Hwan(김지환) ORCID logo https://orcid.org/0000-0002-0872-4906
Moon, Hong Seok(문홍석) ORCID logo https://orcid.org/0000-0001-8118-8145
Oh, Kyung Chul(오경철) ORCID logo https://orcid.org/0000-0003-4584-2597
Woo, Chang Woo(우창우)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/170432
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links