444 614

Cited 0 times in

Grooved abutment가 임플란트 지대주 연결나사의 안정성에 미치는 영향

Other Titles
 Effects of grooved abutment on stability of implant abutment screw 
Authors
 심일광  ;  양승원  ;  심준성  ;  김지환 
Citation
 Journal of Korean Academy of Prosthodontics (대한치과보철학회지), Vol.54(4) : 387-392, 2016 
Journal Title
Journal of Korean Academy of Prosthodontics(대한치과보철학회지)
ISSN
 0301-2875 
Issue Date
2016
Keywords
Grooved abutment ; Additional rotational angle ; Screw loosening,
Abstract
Purpose: The aim of this study was to investigate the effects of grooved abutments on abutment screw loosening. Materials and methods: This study was conducted to evaluate the abutment screw loosening after 6 months for 50 patients (51 implants) treated at the department of Prosthodontics in Yonsei University Dental Hospital from March, 2015 to July, 2015. A control group with non-grooved abutment consists of 30 implants, and an experimental group with grooved abutment consists of 21 implants. Astra, Straumann, Implantium, Osstem system were used in the study. The abutments with loose screws cases after a period of 6 months has been investigated, with two kinds of measurements: 1) measuring the additional rotational angle on abutment during placement with the same force, 2) measuring the PTV on bucco-cervical area of implant crown. All data collected has been analyzed by normality test followed by Mann-Whitney test using SPSS program. Results: No complications were reported after 6 months for the 51 implants. Abutment screw loose and crown fracture have not been seen in the study groups. The data collected from the two measurements showed no significant differences between the two groups with P-value 0.576 (average= control group: $7.35℃, experimental group: $4.75^{\circ}$) for the additional rotational angle measurement and with P-value 0.767 for PTV. Conclusion: There are no significant differences between the grooved and non-grooved abutment in screw stability. However, further studies with long-term followups and larger group of patients is needed in order to investigate the effects of grooved abutment on screw stability.
Files in This Item:
T201606824.pdf Download
DOI
10.4047/jkap.2016.54.4.387
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Jee Hwan(김지환) ORCID logo https://orcid.org/0000-0002-0872-4906
Shim, June Sung(심준성) ORCID logo https://orcid.org/0000-0003-1428-0122
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/167883
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links