Cited 9 times in
Feasibility of radiation dose reduction with iterative reconstruction in abdominopelvic CT for patients with inappropriate arm positioning
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김명진 | - |
dc.contributor.author | 박미숙 | - |
dc.contributor.author | 서니은 | - |
dc.contributor.author | 안찬식 | - |
dc.contributor.author | 정용은 | - |
dc.contributor.author | 최진영 | - |
dc.date.accessioned | 2019-02-12T16:47:42Z | - |
dc.date.available | 2019-02-12T16:47:42Z | - |
dc.date.issued | 2018 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/167146 | - |
dc.description.abstract | BACKGROUND: The arms-down position increases computed tomography (CT) radiation dose. Iterative reconstruction (IR) could enhance image quality without increasing radiation dose in patients with arms-down position. AIM: To investigate the feasibility of reduced-dose CT with IR for patients with inappropriate arm positioning. METHODS: Twenty patients who underwent two-phase abdominopelvic CT including standard-dose and reduced-dose CT (performed with 80% of the radiation dose of the standard protocol) with their arms positioned in the abdominal area were included in this study. Reduced-dose CT images were reconstructed using filtered back projection (FBP), hybrid IR, and iterative model reconstruction (IMR). These images were compared with standard-dose CT images reconstructed with FBP. Objective image noise in the liver and subcutaneous fat was measured by standard deviation for the quantitative analysis. Then, two radiologists qualitatively assessed beam hardening artifacts, artificial texture, noise, sharpness, and overall image quality in consensus. RESULTS: Reduced-dose CT with all IR levels had lower objective image noise compared to standard-dose CT with FBP reconstruction (P < 0.05). Quantitatively measured beam hardening artifacts were similar in reduced-dose CT with iDose levels 5-6 and fewer with IMR compared to standard-dose CT. In the qualitative analysis, beam hardening artifacts and noise decreased as the IR levels increased. However, artificial texture was significantly aggravated with iDose 5-6 and IMR, and overall image quality significantly worsened with IMR. CONCLUSIONS: IR algorithms can reduce beam hardening artifacts in a reduced-dose CT setting in patients with arms-down position, and an intermediate level of hybrid IR allows radiologists to obtain the best image quality. Because the retrospective and single-center nature of our study limited the number of patients, multicenter prospective clinical studies are required to validate our results. | - |
dc.description.statementOfResponsibility | open | - |
dc.format | application/pdf | - |
dc.language | English | - |
dc.publisher | Public Library of Science | - |
dc.relation.isPartOf | PLOS ONE | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | Feasibility of radiation dose reduction with iterative reconstruction in abdominopelvic CT for patients with inappropriate arm positioning | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Radiology (영상의학교실) | - |
dc.contributor.googleauthor | Nieun Seo | - |
dc.contributor.googleauthor | Yong Eun Chung | - |
dc.contributor.googleauthor | Chansik An | - |
dc.contributor.googleauthor | Jin-Young Choi | - |
dc.contributor.googleauthor | Mi-Suk Park | - |
dc.contributor.googleauthor | Myeong-Jin Kim | - |
dc.identifier.doi | 10.1371/journal.pone.0209754 | - |
dc.contributor.localId | A00426 | - |
dc.contributor.localId | A01463 | - |
dc.contributor.localId | A01874 | - |
dc.contributor.localId | A02268 | - |
dc.contributor.localId | A03662 | - |
dc.contributor.localId | A04200 | - |
dc.relation.journalcode | J02540 | - |
dc.identifier.eissn | 1932-6203 | - |
dc.identifier.pmid | 30596739 | - |
dc.contributor.alternativeName | Kim, Myeong Jin | - |
dc.contributor.affiliatedAuthor | 김명진 | - |
dc.contributor.affiliatedAuthor | 박미숙 | - |
dc.contributor.affiliatedAuthor | 서니은 | - |
dc.contributor.affiliatedAuthor | 안찬식 | - |
dc.contributor.affiliatedAuthor | 정용은 | - |
dc.contributor.affiliatedAuthor | 최진영 | - |
dc.citation.volume | 13 | - |
dc.citation.number | 12 | - |
dc.citation.startPage | e0209754 | - |
dc.identifier.bibliographicCitation | PLOS ONE, Vol.13(12) : e0209754, 2018 | - |
dc.identifier.rimsid | 58126 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.