0 490

Cited 80 times in

CT sinogram-consistency learning for metal-induced beam hardening correction

DC Field Value Language
dc.contributor.author정용은-
dc.date.accessioned2019-01-15T17:08:19Z-
dc.date.available2019-01-15T17:08:19Z-
dc.date.issued2018-
dc.identifier.issn0094-2405-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/166827-
dc.description.abstractPURPOSE: This paper proposes a sinogram-consistency learning method to deal with beam hardening-related artifacts in polychromatic computerized tomography (CT). The presence of highly attenuating materials in the scan field causes an inconsistent sinogram that does not match the range space of the Radon transform. When the mismatched data are entered into the range space during CT reconstruction, streaking and shading artifacts are generated owing to the inherent nature of the inverse Radon transform METHODS: The proposed learning method aims to repair inconsistent sinogram by removing the primary metal-induced beam hardening factors along the metal trace in the sinogram. Taking account of the fundamental difficulty in obtaining sufficient training data in a medical environment, the learning method is designed to use simulated training data and a patient's implant type-specific learning model is used to simplify the learning process. RESULTS: The feasibility of the proposed method is investigated using a dataset, consisting of real CT scans of pelvises containing simulated hip prostheses. The anatomical areas in training and test data are different, in order to demonstrate that the proposed method extracts the beam hardening features, selectively. The results show that our method successfully corrects sinogram inconsistency by extracting beam hardening sources by means of deep learning. CONCLUSION: This paper proposed a deep learning method of sinogram correction for beam hardening reduction in CT for the first time. Conventional methods for beam hardening reduction are based on regularizations, and have the fundamental drawback of being not easily able to use manifold CT images, while a deep learning approach has the potential to do so.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherPublished for the American Assn. of Physicists in Medicine by the American Institute of Physics.-
dc.relation.isPartOfMEDICAL PHYSICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleCT sinogram-consistency learning for metal-induced beam hardening correction-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학교실)-
dc.contributor.googleauthorHyoung Suk Park-
dc.contributor.googleauthorSung Min Lee-
dc.contributor.googleauthorHwa Pyung Kim , Jin Keun Seo , Yong Eun Chung-
dc.identifier.doi10.1002/mp.13199-
dc.contributor.localIdA03662-
dc.relation.journalcodeJ02206-
dc.identifier.eissn2473-4209-
dc.identifier.pmid30238586-
dc.identifier.urlhttps://aapm.onlinelibrary.wiley.com/doi/full/10.1002/mp.13199-
dc.subject.keywordcomputerized tomography-
dc.subject.keyworddeep learning-
dc.subject.keywordmetal artifact reduction-
dc.subject.keywordtomographic image reconstruction-
dc.contributor.alternativeNameChung, Yong Eun-
dc.contributor.affiliatedAuthor정용은-
dc.citation.volume45-
dc.citation.number12-
dc.citation.startPage5376-
dc.citation.endPage5384-
dc.identifier.bibliographicCitationMEDICAL PHYSICS, Vol.45(12) : 5376-5384, 2018-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.