0 564

Cited 3 times in

Enhancement of refractive outcomes of small-incision lenticule extraction via tear-film control

Authors
 Il Hwan Koh  ;  Kyoung Yul Seo  ;  Seong Bae Park  ;  Hun Yang  ;  InSik Kim  ;  Sang Min Nam 
Citation
 GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, Vol.256(11) : 2259-2268, 2018 
Journal Title
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY
ISSN
 0721-832X 
Issue Date
2018
MeSH
Adult ; Case-Control Studies ; Corneal Stroma/surgery ; Corneal Surgery, Laser/methods* ; Corneal Topography ; Female ; Humans ; Male ; Microscopy, Electron, Scanning ; Microsurgery ; Myopia/physiopathology ; Myopia/surgery* ; Refraction, Ocular/physiology* ; Retrospective Studies ; Tears/physiology* ; Visual Acuity/physiology ; Young Adult
Keywords
Predictability ; Refractive outcome ; Small-incision lenticule extraction ; Stability ; Tear film
Abstract
PURPOSE: To suggest that tear film is a refractive outcome predictor in small-incision lenticule extraction (SMILE) for myopia and describe methods of controlling the tear film and its effects on refractive outcomes.

METHODS: In this retrospective case-control study, the tear film was kept clear and appropriate in amount during tear-film-controlled SMILE (TFC-SMILE). In contrast, no special care to the tear film was given in direct-docking SMILE (DD-SMILE). Both procedures were performed by the same experienced surgeon, using the same surgical parameters, over defined periods. In select cases, scanning electron microscopy (SEM) of the lenticule and surgical videos of opaque bubble layers (OBLs) were obtained and compared.

RESULTS: Forty-one eyes had DD-SMILE and 55 eyes had TFC-SMILE. Multivariate analysis showed that TFC-SMILE and the patient's age were significant predictors of refractive outcomes. The refractive predictability of TFC-SMILE was better than that of DD-SMILE, and under-correction of high myopia was evident in the latter patients. The predictive errors of DD-SMILE became more myopic and variable during 1 year than those of TFC-SMILE. The lenticular surface on SEM was more serrated in DD-SMILE. Severe OBLs were evident in four cases of DD-SMILE and the OBL pattern was sporadic at the anterior surface of the lenticule.

CONCLUSIONS: The presence of a clear and appropriate tear film in SMILE enhanced predictability, minimized variability, and ensured stability of refractive outcomes. An uncontrolled tear film might render cutting imprecise and trigger severe OBL formation. TFC-SMILE had more predictable results than DD-SMILE.
Full Text
https://link.springer.com/article/10.1007%2Fs00417-018-4074-x
DOI
10.1007/s00417-018-4074-x
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers
Yonsei Authors
Seo, Kyoung Yul(서경률) ORCID logo https://orcid.org/0000-0002-9855-1980
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/166812
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links