1073 700

Cited 0 times in

Computer-designed surgical guide를 이용한 임플란트 식립 시의 정확도 평가: a case series

Other Titles
 Accuracy evaluation of implant placement with computer-designed surgical guide: a case series 
Authors
 강주현  ;  김진구  ;  배형철  ;  박진영  ;  차재국  ;  최성호 
Citation
 Journal of Korean Academy of Osseointegration (대한인공치아골유착학회지), Vol.9(2) : 24-28, 2017 
Journal Title
Journal of Korean Academy of Osseointegration(대한인공치아골유착학회지)
Issue Date
2017
Keywords
Computer-aided design/computer-assisted manufacture ; Computed tomography ; Implant ; Surgical guide
Abstract
come more and more popular in clinic. This digital guide template seems to express great potential for accuracy and simplification. However, it is not completely clear whether the surgical template can actually increase the accuracy of the implant.Purpose: The purpose of this study was to assess the accuracy of implant placement using surgical guide templates.Materials & Methods: A total of 4 patients with missing teeth were included in our study. Preoperative cone beam computed tomography (CBCT) was performed and preoperative planning was designed with softwarefor all patients. Implant surgical guide templates were designed and produced by a RP technique. Postoperative CBCT was performed for all patients. Image registration was carried out between postoperative CBCT data and that of preoperative planning data. Deviations of the implant between the actual and planned positions were measured and compared.Results: The overall mean deviation at the entry point was 0.63±0.37 mm and at the apex was 0.62±0.43 mm in buccolingual direction and at the apical direction was 0.39±0.33. Finally, the mean deviation of implant angulation was 0.75±0.67o.Conclusions: The result of implant position placed with surgical guide templates has not significant difference from planned position in implant shoulder, apex, and angulation. Thus, is much more suitable for complicated procedures and conditions such as the flapless method, immediate loading, aesthetic restoration, and insufficient bone height.
Files in This Item:
T999901425.pdf Download
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Periodontics (치주과학교실) > 1. Journal Papers
Yonsei Authors
Cha, Jae Kook(차재국) ORCID logo https://orcid.org/0000-0001-6817-9834