Cited 2 times in
Balloon-Supported Passage of a Stent-Graft into the Aortic Arch
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 송석원 | - |
dc.contributor.author | 은나래 | - |
dc.contributor.author | 이광훈 | - |
dc.date.accessioned | 2018-11-01T16:40:47Z | - |
dc.date.available | 2018-11-01T16:40:47Z | - |
dc.date.issued | 2015 | - |
dc.identifier.issn | 1229-6929 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/164982 | - |
dc.description.abstract | A 62-year-old man was admitted, and thoracic endovascular aortic repair (TEVAR) procedure was performed to treat an accidentally detected aortic aneurysm, which was 63 mm in diameter. While performing TEVAR, the passage of the stent-graft introducer system was impossible due to the prolapse of the introducer system into a wide-necked aneurysm; this aneurysm was located at the greater curvature of the proximal descending thoracic aorta. In order to advance the introducer system, a compliant balloon was inflated. Thus, we created an artificial wall in the aneurysm with this inflated balloon. Finally, we were able to advance the introducer system into the target zone. | - |
dc.description.statementOfResponsibility | open | - |
dc.format | application/pdf | - |
dc.language | English | - |
dc.publisher | Korean Society of Radiology | - |
dc.relation.isPartOf | KOREAN JOURNAL OF RADIOLOGY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | Balloon-Supported Passage of a Stent-Graft into the Aortic Arch | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Thoracic and Cardiovascular Surgery (흉부외과학교실) | - |
dc.contributor.googleauthor | Na Lae Eun | - |
dc.contributor.googleauthor | Dahye Lee | - |
dc.contributor.googleauthor | Suk-Won Song | - |
dc.contributor.googleauthor | Seung-Moon Joo | - |
dc.contributor.googleauthor | Tilo Kölbel | - |
dc.contributor.googleauthor | Kwang-Hun Lee | - |
dc.identifier.doi | 10.3348/kjr.2015.16.4.744 | - |
dc.contributor.localId | A02028 | - |
dc.contributor.localId | A04778 | - |
dc.contributor.localId | A02676 | - |
dc.relation.journalcode | J02884 | - |
dc.identifier.eissn | 2005-8330 | - |
dc.identifier.pmid | 26175573 | - |
dc.subject.keyword | Aortic arch | - |
dc.subject.keyword | Balloon-supported passage of an introducer system | - |
dc.subject.keyword | Proximal descending thoracic aorta | - |
dc.subject.keyword | Thoracic aortic aneurysm | - |
dc.subject.keyword | Thoracic endovascular aortic repair | - |
dc.subject.keyword | Wide-necked aneurysm | - |
dc.contributor.alternativeName | Song, Suk Won | - |
dc.contributor.alternativeName | Eun, Na Lae | - |
dc.contributor.alternativeName | Lee, Kwang Hun | - |
dc.contributor.affiliatedAuthor | 송석원 | - |
dc.contributor.affiliatedAuthor | 은나래 | - |
dc.contributor.affiliatedAuthor | 이광훈 | - |
dc.citation.volume | 16 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 744 | - |
dc.citation.endPage | 748 | - |
dc.identifier.bibliographicCitation | KOREAN JOURNAL OF RADIOLOGY, Vol.16(4) : 744-748, 2015 | - |
dc.identifier.rimsid | 58305 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.