A rare case of interparietal incisional hernia from 8 mm trocar site after robot-assisted laparoscopic prostatectomy

Authors
 S. K. Lim  ;  K. H. Kim  ;  T.-Y. Shin  ;  S. J. Hong  ;  Y. D. Choi  ;  K. H. Rha 
Citation
 HERNIA, Vol.18(6) : 911-913, 2014 
Journal Title
HERNIA
ISSN
 1265-4906 
Issue Date
2014
MeSH
Adenocarcinoma/surgery* ; Hernia, Ventral/etiology* ; Hernia, Ventral/surgery ; Humans ; Laparoscopy/adverse effects* ; Laparoscopy/instrumentation ; Male ; Middle Aged ; Prostatectomy ; Prostatic Neoplasms/surgery* ; Robotic Surgical Procedures ; Surgical Instruments/adverse effects
Abstract
Trocar site hernia arising from 8 mm robotic port is very rare despite the increasing prevalence of robot-assisted surgeries. To date, there had been only a single case reported in the literature. We report a case of small bowel obstruction secondary to an interparietal trocar site incisional hernia after robot-assisted laparoscopic prostatectomy. Meticulous closure of 8 mm robotic trocar sites associated with large peritoneal defect at the end of surgery should be performed.