Background:

The use of capnography monitoring devices has been shown to lower the rates of hypoxemia via early detection of respiratory depression, and facilitate more accurate titration of sedatives during procedures. The aim of the current meta-analysis was to compare the incidence of hypoxemia associated with standard monitoring alone during gastrointestinal endoscopy to that associated with standard monitoring with the addition of capnography.

Methods:

The MEDLINE, EMBASE, and Cochrane Central Register of Controlled Trials scientific databases were searched to identify relevant studies. We performed a meta-analysis of randomized controlled trials undertaken up to January 2018 that met our predefined inclusion criteria. The study outcome measures were incidence of hypoxemia, severe hypoxemia, apnea, the use of assisted ventilation, the use of supplemental oxygen, and change in vital signs.

Results:

We included nine trials assessing a total of 3,088 patients who underwent gastrointestinal procedural sedation. Meta-analysis of study outcome revealed that capnography significantly reduced the incidence of hypoxemia (odds ratio 0.61, 95% CI 0.49-0.77) and severe hypoxemia (odds ratio 0.53, 95% CI 0.35-0.81). However, there were no significant differences in other outcomes including incidence of apnea, assisted ventilation, supplemental oxygen, and changes in vital signs. Early procedure termination and patient satisfaction-related outcomes did not differ significantly in the capnography group and the standard monitoring group.

Conclusion:

This study indicates that capnography monitoring is an important addition with regard to the detection of hypoxemia during gastrointestinal procedural sedation, and should be considered in routine monitoring during gastrointestinal endoscopy.
Files in This Item:
T201802797.pdf Download
DOI
10.2147/TCRM.S174698
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Anesthesiology and Pain Medicine (마취통증의학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Yonsei Biomedical Research Center (연세의생명연구원) > 1. Journal Papers
Yonsei Authors
Kim, Seung Hyun(김승현) ORCID logo https://orcid.org/0000-0003-2127-6324
Kim, Eungjin(김응진) ORCID logo https://orcid.org/0000-0002-1934-7982
Lee, Jinae(이진애)
Choi, Yong Seon(최용선) ORCID logo https://orcid.org/0000-0002-5348-864X
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/163459
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links