Evaluation of PM10, CO2, airborne bacteria, TVOCs, and formaldehyde in facilities for susceptible populations in South Korea

Authors
 Sung Ho Hwang  ;  Jaehoon Roh  ;  Wha Me Park 
Citation
 ENVIRONMENTAL POLLUTION, Vol.242(Pt A) : 700-708, 2018 
Journal Title
ENVIRONMENTAL POLLUTION
ISSN
 0269-7491 
Issue Date
2018
Keywords
Airborne bacteria ; Carbon dioxide ; Formaldehyde ; PM(10) ; Susceptible population ; Total volatile organic compounds
Abstract
Poor indoor air quality can have adverse effects on human health, especially in susceptible populations; however, few studies have measured multiple pollutants in facilities for susceptible populations at a national scale in South Korea. Therefore, we measured the concentrations of indoor pollutants (fine particulate matter (PM10), CO2, airborne bacteria (AB), total volatile organic compounds (TVOCs), and formaldehyde) to determine their possible relation to other indoor environmental factors and characteristics of facilities with susceptible populations, such as hospitals, geriatric hospitals, elderly care facilities, and postnatal care centers throughout South Korea. Indoor pollutants were sampled at 82 indoor facilities, including 62 facilities for susceptible populations. Spearman's correlation, Kruskal-Wallis, and Mann-Whitney analyses were used to examine the relationship among and differences between pollutants at indoor facilities and indoor/outdoor differences in PM10 concentration. There were significant correlations between indoor temperature and AB concentration (r = 0.37, p < 0.01), TVOCs, and formaldehyde (r = 0.264, p < 0.01). Indoor PM10 concentrations were higher than outdoor concentrations at all facilities for susceptible populations (p < 0.01). CO2 might be a good indicator for predicting indoor pollutants when categorized into two levels (≤750 ppm and >750 ppm). The hazard quotient of formaldehyde was higher than the acceptable level of 1 for children under the age of eight in postnatal care centers, indicative of unsafe levels. Therefore, more depth study for exposure characteristics of formaldehyde and indoor air quality (IAQ) in postnatal care facilities as a national scale is needed for finding the children exposure levels.
Full Text
https://www.sciencedirect.com/science/article/pii/S0269749118314386
DOI
10.1016/j.envpol.2018.07.013
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Preventive Medicine (예방의학교실) > 1. Journal Papers
Yonsei Authors
Roh, Jae Hoon(노재훈)
Park, Wha Me(박화미) ORCID logo https://orcid.org/0000-0002-7499-0663
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/163203
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links