A whole-heart motion-correction algorithm: Effects on CT image quality and diagnostic accuracy of mechanical valve prosthesis abnormalities

DC Field Value Language
dc.contributor.author김영진-
dc.contributor.author김진영-
dc.contributor.author서영주-
dc.contributor.author임동진-
dc.contributor.author장수연-
dc.contributor.author최병욱-
dc.contributor.author홍유진-
dc.date.accessioned2018-07-20T12:05:42Z-
dc.date.available2018-07-20T12:05:42Z-
dc.date.issued2017-
dc.identifier.issn1934-5925-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/161773-
dc.description.abstractBACKGROUND: We aimed to determine the effect of a whole-heart motion-correction algorithm (new-generation snapshot freeze, NG SSF) on the image quality of cardiac computed tomography (CT) images in patients with mechanical valve prostheses compared to standard images without motion correction and to compare the diagnostic accuracy of NG SSF and standard CT image sets for the detection of prosthetic valve abnormalities. METHODS: A total of 20 patients with 32 mechanical valves who underwent wide-coverage detector cardiac CT with single-heartbeat acquisition were included. The CT image quality for subvalvular (below the prosthesis) and valvular regions (valve leaflets) of mechanical valves was assessed by two observers on a four-point scale (1 = poor, 2 = fair, 3 = good, and 4 = excellent). Paired t-tests or Wilcoxon signed rank tests were used to compare image quality scores and the number of diagnostic phases (image quality score≥3) between the standard image sets and NG SSF image sets. Diagnostic performance for detection of prosthetic valve abnormalities was compared between two image sets with the final diagnosis set by re-operation or clinical findings as the standard reference. RESULTS: NG SSF image sets had better image quality scores than standard image sets for both valvular and subvalvular regions (P < 0.05 for both). The number of phases that were of diagnostic image quality per patient was significantly greater in the NG SSF image set than standard image set for both valvular and subvalvular regions (P < 0.0001). Diagnostic performance of NG SSF image sets for the detection of prosthetic abnormalities (20 pannus and two paravalvular leaks) was greater than that of standard image sets (P < 0.05). CONCLUSION: Application of NG SSF can improve CT image quality and diagnostic accuracy in patients with mechanical valves compared to standard images.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherElsevier-
dc.relation.isPartOfJOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleA whole-heart motion-correction algorithm: Effects on CT image quality and diagnostic accuracy of mechanical valve prosthesis abnormalities-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Radiology-
dc.contributor.googleauthorYoung Joo Suh-
dc.contributor.googleauthorYoung Jin Kim-
dc.contributor.googleauthorJin Young Kim-
dc.contributor.googleauthorSuyon Chang-
dc.contributor.googleauthorDong Jin Im-
dc.contributor.googleauthorYoo Jin Hong-
dc.contributor.googleauthorByoung Wook Choi-
dc.identifier.doi10.1016/j.jcct.2017.09.011-
dc.contributor.localIdA00727-
dc.contributor.localIdA05113-
dc.contributor.localIdA01892-
dc.contributor.localIdA03361-
dc.contributor.localIdA03444-
dc.contributor.localIdA04059-
dc.contributor.localIdA04422-
dc.relation.journalcodeJ01291-
dc.identifier.eissn1876-861X-
dc.identifier.pmid28966103-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S1934592517302149-
dc.subject.keywordArtifacts-
dc.subject.keywordComputed tomography-
dc.subject.keywordDiagnostic accuracy-
dc.subject.keywordHeart valve prostheses-
dc.subject.keywordImage quality-
dc.subject.keywordMotion correction-
dc.contributor.alternativeNameKim, Young Jin-
dc.contributor.alternativeNameKim, Jin Young-
dc.contributor.alternativeNameSuh, Young Joo-
dc.contributor.alternativeNameIm, Dong Jin-
dc.contributor.alternativeNameChang, Su Yon-
dc.contributor.alternativeNameChoi, Byoung Wook-
dc.contributor.alternativeNameHong, Yoo Jin-
dc.contributor.affiliatedAuthorKim, Young Jin-
dc.contributor.affiliatedAuthorKim, Jin Young-
dc.contributor.affiliatedAuthorSuh, Young Joo-
dc.contributor.affiliatedAuthorIm, Dong Jin-
dc.contributor.affiliatedAuthorChang, Su Yon-
dc.contributor.affiliatedAuthorChoi, Byoung Wook-
dc.contributor.affiliatedAuthorHong, Yoo Jin-
dc.citation.volume11-
dc.citation.number6-
dc.citation.startPage474-
dc.citation.endPage481-
dc.identifier.bibliographicCitationJOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, Vol.11(6) : 474-481, 2017-
dc.identifier.rimsid59387-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.