Acute Pulmonary Embolism: Retrospective Cohort Study of the Predictive Value of Perfusion Defect Volume Measured With Dual-Energy CT

DC Field Value Language
dc.contributor.author김영진-
dc.contributor.author이혜정-
dc.contributor.author임동진-
dc.contributor.author최병욱-
dc.contributor.author허진-
dc.date.accessioned2018-07-20T11:55:23Z-
dc.date.available2018-07-20T11:55:23Z-
dc.date.issued2017-
dc.identifier.issn0361-803X-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/161499-
dc.description.abstractOBJECTIVE: The purposes of this study were to investigate dual-energy CT findings predictive of clinical outcome and to determine the incremental risk stratification benefit of dual-energy CT findings compared with CT ventricular diameter ratio in patients with acute pulmonary embolism. MATERIALS AND METHODS: A retrospective evaluation was conducted of the cases of 172 patients with acute pulmonary embolism who underwent dual-energy CT. Ventricular diameter ratio and relative perfusion defect volume were measured. The primary endpoints were death within 30 days and pulmonary embolism-related death. RESULTS: A ventricular diameter ratio of 1 or greater was associated with increased risk of death within 30 days (hazard ratio, 3.822; p = 0.002) and pulmonary embolism-related death (hazard ratio, 18.051; p < 0.001). Relative perfusion defect volume was also associated with increased risk of death of any cause within 30 days (hazard ratio, 1.044; p = 0.014) and pulmonary embolism-related death (hazard ratio, 1.046; p = 0.017). However, the addition of relative perfusion defect volume to ventricular diameter ratio had no added benefit for prediction of death of any cause within 30 days (concordance statistic, 0.833 vs 0.815; p = 0.187) or pulmonary embolism-related death (concordance statistic, 0.873 vs 0.874; p = 0.866). CONCLUSION: Compared with ventricular diameter ratio alone, lung perfusion defect volume had no statistically significant added benefit for prediction of death of any cause within 30 days or of pulmonary embolism-related death among patients with acute PE.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherSpringfield, Ill., Thomas-
dc.relation.isPartOfAMERICAN JOURNAL OF ROENTGENOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAcute Disease-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHAged, 80 and over-
dc.subject.MESHAngiography*-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHPredictive Value of Tests-
dc.subject.MESHPulmonary Circulation-
dc.subject.MESHPulmonary Embolism/diagnostic imaging*-
dc.subject.MESHPulmonary Embolism/mortality-
dc.subject.MESHPulmonary Embolism/therapy-
dc.subject.MESHRetrospective Studies-
dc.subject.MESHTomography, X-Ray Computed*-
dc.subject.MESHTreatment Outcome-
dc.subject.MESHYoung Adult-
dc.titleAcute Pulmonary Embolism: Retrospective Cohort Study of the Predictive Value of Perfusion Defect Volume Measured With Dual-Energy CT-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Radiology-
dc.contributor.googleauthorDong Jin Im-
dc.contributor.googleauthorJin Hur-
dc.contributor.googleauthorKyung Hwa Han-
dc.contributor.googleauthorHye-Jeong Lee-
dc.contributor.googleauthorYoung Jin Kim-
dc.contributor.googleauthorWoocheol Kwon-
dc.contributor.googleauthorByoung Wook Choi-
dc.identifier.doi10.2214/AJR.17.17815-
dc.contributor.localIdA00727-
dc.contributor.localIdA03320-
dc.contributor.localIdA03361-
dc.contributor.localIdA04059-
dc.contributor.localIdA04370-
dc.relation.journalcodeJ00116-
dc.identifier.eissn1546-3141-
dc.identifier.pmid28898127-
dc.identifier.urlhttps://www.ajronline.org/doi/abs/10.2214/AJR.17.17815-
dc.subject.keywordDECT-
dc.subject.keywordacute pulmonary embolism-
dc.subject.keyworddual-energy CT-
dc.subject.keywordlung perfusion-
dc.subject.keywordventricular diameter-
dc.contributor.alternativeNameKim, Young Jin-
dc.contributor.alternativeNameLee, Hye Jeong-
dc.contributor.alternativeNameIm, Dong Jin-
dc.contributor.alternativeNameChoi, Byoung Wook-
dc.contributor.alternativeNameHur, Jin-
dc.contributor.affiliatedAuthorKim, Young Jin-
dc.contributor.affiliatedAuthorLee, Hye Jeong-
dc.contributor.affiliatedAuthorIm, Dong Jin-
dc.contributor.affiliatedAuthorChoi, Byoung Wook-
dc.contributor.affiliatedAuthorHur, Jin-
dc.citation.volume209-
dc.citation.number5-
dc.citation.startPage1015-
dc.citation.endPage1022-
dc.identifier.bibliographicCitationAMERICAN JOURNAL OF ROENTGENOLOGY, Vol.209(5) : 1015-1022, 2017-
dc.identifier.rimsid61406-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.