385 696

Cited 6 times in

Three-Dimensional Fast Spin-Echo Imaging without Fat Suppression of the Knee: Diagnostic Accuracy Comparison to Fat-Suppressed Imaging on 1.5T MRI.

DC Field Value Language
dc.contributor.author김형식-
dc.contributor.author박진오-
dc.contributor.author서진석-
dc.contributor.author이영한-
dc.contributor.author정수윤-
dc.contributor.author조희우-
dc.date.accessioned2018-07-20T08:37:21Z-
dc.date.available2018-07-20T08:37:21Z-
dc.date.issued2017-
dc.identifier.issn0513-5796-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/161330-
dc.description.abstractPURPOSE: To evaluate the diagnostic performance of three-dimensional fast spin-echo (3D FSE-Cube) without fat suppression (NFS) for detecting knee lesions, using comparison to 3D FSE-Cube with fat suppression (FS). MATERIALS AND METHODS: One hundred twenty-four patients who underwent 1.5T knee magnetic resonance imaging (MRI) scans and 25 subsequent arthroscopic surgeries were retrospectively reviewed. Using arthroscopic results and two-dimensional images as reference standards, diagnostic performances of 3D FSE-Cube-NFS and FS imaging about lesions of ligament, meniscus, subchondral bone marrow edema (BME), and cartilage were compared. Scan parameters of 3D FSE-Cube imaging were previously optimized by a porcine knee phantom. RESULTS: No significant differences were observed between detection rates of NFS and FS imaging for detecting lesions of meniscus and cartilage (p>0.05). However, NFS imaging had lower sensitivity for detection of medial collateral ligament (MCL) tears, and lower sensitivity and specificity for detection of BME lesions, compared to FS imaging (p<0.05). CONCLUSION: 3D FSE-Cube-NFS imaging showed similar diagnostic performance for detecting lesions of meniscus or cartilage compared to FS imaging, unlike MCL or BME lesions.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherYonsei University-
dc.relation.isPartOfYONSEI MEDICAL JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHAnimals-
dc.subject.MESHArthroscopy/methods*-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHImaging, Three-Dimensional/methods*-
dc.subject.MESHKnee Joint/diagnostic imaging*-
dc.subject.MESHKnee Joint/pathology-
dc.subject.MESHMagnetic Resonance Imaging/methods*-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHPhantoms, Imaging-
dc.subject.MESHPredictive Value of Tests-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHRetrospective Studies-
dc.subject.MESHSensitivity and Specificity-
dc.subject.MESHSwine-
dc.titleThree-Dimensional Fast Spin-Echo Imaging without Fat Suppression of the Knee: Diagnostic Accuracy Comparison to Fat-Suppressed Imaging on 1.5T MRI.-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Orthopedic Surgery-
dc.contributor.googleauthorHee Woo Cho-
dc.contributor.googleauthorJin-Suck Suh-
dc.contributor.googleauthorJin-Oh Park-
dc.contributor.googleauthorHyoung-Sik Kim-
dc.contributor.googleauthorSoo Yoon Chung-
dc.contributor.googleauthorYoung Han Lee-
dc.contributor.googleauthorSeok Hahn-
dc.identifier.doi10.3349/ymj.2017.58.6.1186-
dc.contributor.localIdA01150-
dc.contributor.localIdA01703-
dc.contributor.localIdA01916-
dc.contributor.localIdA02967-
dc.contributor.localIdA03636-
dc.contributor.localIdA03945-
dc.relation.journalcodeJ02813-
dc.identifier.eissn1976-2437-
dc.identifier.pmid29047243-
dc.subject.keywordCube-
dc.subject.keywordKnee-
dc.subject.keywordfat suppression-
dc.subject.keywordmagnetic resonance imaging-
dc.subject.keywordthree-dimensional image-
dc.contributor.alternativeNameKim, Hyoung Sik-
dc.contributor.alternativeNamePark, Jin Oh-
dc.contributor.alternativeNameSuh, Jin Suck-
dc.contributor.alternativeNameLee, Young Han-
dc.contributor.alternativeNameChung, Soo Yoon-
dc.contributor.alternativeNameCho, Hee Woo-
dc.contributor.affiliatedAuthorKim, Hyoung Sik-
dc.contributor.affiliatedAuthorPark, Jin Oh-
dc.contributor.affiliatedAuthorSuh, Jin Suck-
dc.contributor.affiliatedAuthorLee, Young Han-
dc.contributor.affiliatedAuthorChung, Soo Yoon-
dc.contributor.affiliatedAuthorCho, Hee Woo-
dc.citation.volume58-
dc.citation.number6-
dc.citation.startPage1186-
dc.citation.endPage1194-
dc.identifier.bibliographicCitationYONSEI MEDICAL JOURNAL, Vol.58(6) : 1186-1194, 2017-
dc.identifier.rimsid61249-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Orthopedic Surgery (정형외과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.