혈액은행 자동화 검사장비 ORTHO VISION를 이용한ABO 항체역가검사의 평가

Other Titles
 Evaluation of the Automated Immunohematology Analyzer ORTHO VISION for ABO Antibody Titration 
Authors
 김반석  ;  박유진  ;  김진주  ;  이은경  ;  김신영  ;  김현옥 
Citation
 Korean Journal of Blood Transfusion (대한수혈학회지), Vol.26(3) : 257-265, 2015 
Journal Title
Korean Journal of Blood Transfusion(대한수혈학회지)
ISSN
 1226-9336 
Issue Date
2015
Keywords
Column agglutination technique ; ABO blood group system ; Antibody ; Titer ; Automation
Abstract
Background: ABO antibody titration is important in cases such as ABO incompatible hemolytic disease of the fetus and newborn (HDFN), ABO incompatible bone marrow, or solid organ transplantation. This study was conducted in order to evaluate usability of ORTHO VISION (Ortho Clinical Diagnostics, Raritan, USA) designed automated ABO antibody titration equipment.

Methods: The isoagglutination titers were determined in 80 subjects (20 A, 20 B, 40 O (anti-A 20, anti-B 20)) using a conventional tube technique, including a 30 minute room temperature phase (CTT), Dithiothreitol treated manual column agglutination technique (MCAT), and automated column agglutination technique (ACAT) by ORTHO VISION. The concordance of titer was compared within one dilution step between the two methods.

Results: The isoagglutinin titers measured by the ACAT with anti-human globulin poly cassette (ACAT_Poly) and anti-human globulin IgG cassette (ACAT_IgG) were the highest and the isoagglutinin titer measured by the MCAT was also higher than that by the CTT. The isoagglutinin titer measured by the ACAT with reverse diluents cassette (ACAT_Reverse) was similar to that measured by the CTT. The concordance of anti-A and anti-B titers between CTT and ACAT_Reverse was 83% and 68%. The concordance of anti-A and anti-B titers between MCAT and ACAT_Poly was 100% and 83%. The concordance of anti-A and anti-B titers between MCAT and ACAT_IgG was 98% and 88%.

Conclusion: Automated isoagglutinin titration using ACAT_Poly or ACAT_IgG without DTT showed reliable concordance with DTT treated MCAT, and it appears to be a possible replacement for the conventional MCAT method.
Files in This Item:
T201506142.pdf Download
DOI
10.17945/kjbt.2015.26.3.257
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Sin Young(김신영) ORCID logo https://orcid.org/0000-0002-2609-8945
Kim, Hyun Ok(김현옥) ORCID logo https://orcid.org/0000-0002-4964-1963
Lee, Eunkyung(이은경)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/157275
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links