0 538

Cited 28 times in

Utility of near-infrared light devices for pediatric peripheral intravenous cannulation: a systematic review and meta-analysis

Authors
 Joon Min Park  ;  Min Joung Kim  ;  Hyeon Woo Yim  ;  Won-Chul Lee  ;  Hyunsuk Jeong  ;  Na Jin Kim 
Citation
 EUROPEAN JOURNAL OF PEDIATRICS, Vol.175(12) : 1975-1988, 2016 
Journal Title
EUROPEAN JOURNAL OF PEDIATRICS
ISSN
 0340-6199 
Issue Date
2016
Abstract
We investigated the utility of near-infrared (NIR) light devices for peripheral intravenous cannulation (PIVC) in pediatric patients. We searched three databases, MEDLINE, EMBASE, and the Cochrane CENTRAL. Randomized controlled trials that compared PIVC using NIR light devices and the "traditional" method (with no assistive device) were included. The primary outcome was a failure rate at the first attempt, and the effect size was measured by the risk ratio for failure. Subgroup analysis was performed according to control group risk for failure at first attempt as an indicator of difficult procedure (low vs. high). Eleven studies were included in the meta-analysis. There was no significant difference in the primary outcome between the two methods (risk ratio 1.03, confidence interval 0.89-1.20, I 2 = 48 %). In a subgroup analysis, the subgroup difference between subsets of low and high control group risk was significant (I 2 = 83 %). In the subset of the high control group risk, using NIR light devices showed a lower risk for failure than the traditional method (risk ratio 0.81, confidence interval 0.64-1.01, I 2 = 0 %).

CONCLUSION: Using NIR light devices did not have an impact on overall failure rate at the first attempt at PIVC in pediatric patients. What is Known: • Near-infrared light devices have been used to help vascular access especially for the pediatric patients. But, their utilities reported in previous studies were conflicting. What is New: • From this study, we could not find out overall benefit of using near-infrared light devices for pediatric peripheral intravenous cannulation. But, this device might be useful for the patients in a difficult condition of successful cannulation.
Full Text
https://link.springer.com/article/10.1007/s00431-016-2796-5
DOI
10.1007/s00431-016-2796-5
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Emergency Medicine (응급의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Min Joung(김민정) ORCID logo https://orcid.org/0000-0003-1634-5209
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/155798
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links