0 714

Cited 45 times in

Intramedullary Nailing for Atypical Femoral Fracture with Excessive Anterolateral Bowing

Authors
 Young-Chang Park  ;  Hyung-Keun Song  ;  Xuan-Lin Zheng  ;  Kyu-Hyun Yang 
Citation
 JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, Vol.99(9) : 726-735, 2017 
Journal Title
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME
ISSN
 0021-9355 
Issue Date
2017
MeSH
Aged ; Aged, 80 and over ; Bone Nails ; Female ; Femoral Fractures/diagnosis ; Femoral Fractures/pathology ; Femoral Fractures/surgery* ; Follow-Up Studies ; Fracture Fixation, Intramedullary/instrumentation ; Fracture Fixation, Intramedullary/methods* ; Humans ; Middle Aged ; Observer Variation ; Retrospective Studies ; Trauma Severity Indices ; Treatment Outcome
Abstract
BACKGROUND: Intramedullary nailing is the treatment of choice for atypical femoral fractures. However, several problems, such as iatrogenic fracture and medial gap opening, can occur during intramedullary nailing when atypical femoral fractures are associated with excessive anterolateral bowing. To overcome these problems, we have developed a new grading system for anterolateral femoral bowing and a new technique for intramedullary nailing. The core of this new technique is matching the anterior curvature of the femoral nail with the anterolateral bowing of the femur when the nail passes the apex of the curvature, by rotating the nail externally.

METHODS: From January 2005 through March 2016, 24 female patients (30 cases) who underwent a surgical procedure for atypical femoral fracture with anterolateral bowing at 2 institutes were evaluated. The postoperative outcomes (anterolateral bowing grade, anterior and lateral bowing angles, medial gap and posterior gap of the fracture site, iatrogenic fracture, and time to initial medial callus formation and osseous union) were compared between the new technique (18 cases) and the conventional technique (12 cases).

RESULTS: With regard to the reliability of the new grading system, the interobserver and intraobserver reliability of the new grading system demonstrated an almost perfect agreement (kappainter = 0.893, kappaintra = 0.883). For patients with complete fractures, the differences between the preoperative and postoperative anterior and lateral bowing angles were significantly less (p = 0.013 for both) in the new technique group. The medial and posterior gaps at the fracture site were also significantly less in the new technique group (p = 0.013 for the medial gaps and p = 0.022 for the posterior gaps). Iatrogenic fracture occurred only in the conventional technique group, affecting 2 cases. The time to initial medial callus formation was significantly shorter (p = 0.033) in the new technique group compared with the conventional technique group.

CONCLUSIONS: Our new grading system for anterolateral femoral bowing is convenient and reliable. Furthermore, the new intramedullary nailing technique with the current intramedullary nail system is appropriate for the repair of atypical femoral fractures with excessive anterolateral bowing.
Full Text
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&CSC=Y&NEWS=N&PAGE=fulltext&AN=00004623-201705030-00003&D=ovft&PDF=y
DOI
10.2106/JBJS.16.00760
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Orthopedic Surgery (정형외과학교실) > 1. Journal Papers
Yonsei Authors
Park, Young Chang(박영창) ORCID logo https://orcid.org/0000-0003-3726-4707
Yang, Kyu Hyun(양규현) ORCID logo https://orcid.org/0000-0001-7183-588X
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/154275
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links