dc.description.abstractEvaluating mechanical valves with computed tomography (CT) can be problematic because artifacts from the metallic components of valves can hamper image quality. The purpose of this study was to determine factors affecting the image quality of cardiac CT to improve assessment of mechanical aortic valves. A total of 144 patients who underwent aortic valve replacement with mechanical valves (ten different types) and who underwent cardiac CT were included. Using a four-point grading system, the image quality of the CT scans was assessed for visibility of the valve leaflets and the subvalvular regions. Data regarding the type of mechanical valve, tube voltage, average heart rate (HR), and HR variability during CT scanning were compared between the non-diagnostic (overall image quality score ≤2) and diagnostic (overall image quality score >2) image quality groups. Logistic regression analyses were performed to identify predictors of non-diagnostic image quality. The percentage of valve types that incorporated a cobalt-chrome component (two types in total) and HR variability were significantly higher in the non-diagnostic image group than in the diagnostic group (P < 0.001 and P = 0.013, respectively). The average HR and tube voltage were not significantly different between the two groups (P > 0.05). Valve type was the only independent predictor of non-diagnostic quality. The CT image quality for patients with mechanical aortic valves differed significantly depending on the type of mechanical valve used and on the degree of HR variability.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherKluwer Academic Publishers-
dc.relation.isPartOfINTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAged-
dc.subject.MESHAortic Valve/diagnostic imaging*-
dc.subject.MESHAortic Valve/physiopathology-
dc.subject.MESHAortic Valve/surgery*-
dc.subject.MESHArtifacts-
dc.subject.MESHCardiac-Gated Imaging Techniques*-
dc.subject.MESHContrast Media/administration & dosage-
dc.subject.MESHDatabases, Factual-
dc.subject.MESHElectrocardiography-
dc.subject.MESHFemale-
dc.subject.MESHHeart Rate-
dc.subject.MESHHeart Valve Prosthesis*-
dc.subject.MESHHeart Valve Prosthesis Implantation/instrumentation*-
dc.subject.MESHHumans-
dc.subject.MESHIopamidol/administration & dosage-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHPredictive Value of Tests-
dc.subject.MESHProsthesis Design-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHRepublic of Korea-
dc.subject.MESHRetrospective Studies-
dc.subject.MESHTomography, X-Ray Computed*-
dc.subject.MESHTreatment Outcome-
dc.titleFactors affecting computed tomography image quality for assessment of mechanical aortic valves-
dc.typeArticle-
dc.publisher.locationUnited States-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Radiology-
dc.contributor.googleauthorYoung Joo Suh-
dc.contributor.googleauthorYoung Jin Kim-
dc.contributor.googleauthorYoo Jin Hong-
dc.contributor.googleauthorHye-Jeong Lee-
dc.contributor.googleauthorJin Hur-
dc.contributor.googleauthorSae Rom Hong-
dc.contributor.googleauthorDong Jin Im-
dc.contributor.googleauthorYun Jung Kim-
dc.contributor.googleauthorByoung Wook Choi-
dc.identifier.doi10.1007/s10554-015-0817-5-
dc.contributor.localIdA01892-
dc.contributor.localIdA03320-
dc.contributor.localIdA03361-
dc.contributor.localIdA04059-
dc.contributor.localIdA04370-
dc.contributor.localIdA04422-
dc.contributor.localIdA00727-
dc.relation.journalcodeJ01094-
dc.identifier.eissn1875-8312-
dc.identifier.pmid26626457-
dc.identifier.urlhttps://link.springer.com/article/10.1007%2Fs10554-015-0817-5-
dc.subject.keywordAortic valve replacement-
dc.subject.keywordCardiac computed tomography-
dc.subject.keywordImage quality-
dc.subject.keywordMechanical valves-
dc.subject.keywordValve type-
dc.contributor.alternativeNameKim, Young Jin-
dc.contributor.alternativeNameSuh, Young Joo-
dc.contributor.alternativeNameLee, Hye Jeong-
dc.contributor.alternativeNameIm, Dong Jin-
dc.contributor.alternativeNameChoi, Byoung Wook-
dc.contributor.alternativeNameHur, Jin-
dc.contributor.alternativeNameHong, Yoo Jin-
dc.contributor.affiliatedAuthorSuh, Young Joo-
dc.contributor.affiliatedAuthorLee, Hye Jeong-
dc.contributor.affiliatedAuthorIm, Dong Jin-
dc.contributor.affiliatedAuthorChoi, Byoung Wook-
dc.contributor.affiliatedAuthorHur, Jin-
dc.contributor.affiliatedAuthorHong, Yoo Jin-
dc.contributor.affiliatedAuthorKim, Young Jin-
dc.citation.volume32-
dc.citation.numberSuppl. 1-
dc.citation.startPage63-
dc.citation.endPage71-
dc.identifier.bibliographicCitationINTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, Vol.32(Suppl. 1) : 63-71, 2016-
dc.date.modified2017-10-24-
dc.identifier.rimsid45834-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.