339 737

Cited 7 times in

Predictors of False-Negative Results from Percutaneous Transthoracic Fine-Needle Aspiration Biopsy: An Observational Study from a Retrospective Cohort

DC Field Value Language
dc.contributor.author김영진-
dc.contributor.author최병욱-
dc.contributor.author허진-
dc.contributor.author홍유진-
dc.contributor.author서영주-
dc.contributor.author이재훈-
dc.contributor.author이혜정-
dc.contributor.author임동진-
dc.date.accessioned2017-10-26T07:15:51Z-
dc.date.available2017-10-26T07:15:51Z-
dc.date.issued2016-
dc.identifier.issn0513-5796-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/151812-
dc.description.abstractPURPOSE: We investigated factors predictive of false-negative pulmonary lesions with nonspecific benign cytology results on percutaneous transthoracic fine-needle aspiration biopsy (FNAB). MATERIALS AND METHODS: We included 222 pulmonary lesions that had a nonspecific benign result from percutaneous transthoracic FNAB between March 2005 and December 2012, and were confirmed by subsequent pathologic results or adequate clinical follow up over at least 2 years. Clinical, imaging, and biopsy procedure-related findings were compared between lesions with a final diagnosis of malignancy (false-negative) and lesions with a benign diagnosis (true-negative). Multivariate logistic regression analysis was performed to identify significant predictors of false-negatives. RESULTS: Of 222 lesions, 115 lesions were proved to be false-negatives, and 107 were true-negatives. Compared with the true-negatives, false-negative lesions showed significantly older age (p=0.037), higher maximum standardized uptake value (SUVmax) on positron emission tomography (p=0.001), larger lesion size (p=0.007), and lesion characteristics of a subsolid nodule (p=0.007). On multivariate logistic regression analysis, SUVmax, lesion size, and lesion characteristics were significant predictors of false-negative results. CONCLUSION: Among the clinical, radiologic, and procedure-related factors analyzed, high SUVmax, large lesion size, and subsolid lesions were useful for predicting malignancy in pulmonary lesions with nonspecific benign cytology results on FNAB.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherYonsei University-
dc.relation.isPartOfYONSEI MEDICAL JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHBiopsy, Fine-Needle/methods*-
dc.subject.MESHCohort Studies-
dc.subject.MESHCytodiagnosis-
dc.subject.MESHFalse Negative Reactions-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHLung/pathology-
dc.subject.MESHLung Diseases/diagnosis*-
dc.subject.MESHLung Diseases/pathology-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHRetrospective Studies-
dc.titlePredictors of False-Negative Results from Percutaneous Transthoracic Fine-Needle Aspiration Biopsy: An Observational Study from a Retrospective Cohort-
dc.typeArticle-
dc.publisher.locationKorea (South)-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Radiology-
dc.contributor.googleauthorYoung Joo Suh-
dc.contributor.googleauthorJae-hoon Lee-
dc.contributor.googleauthorJin Hur-
dc.contributor.googleauthorSae Rom Hong-
dc.contributor.googleauthorDong Jin Im-
dc.contributor.googleauthorYun Jung Kim-
dc.contributor.googleauthorYoo Jin Hong-
dc.contributor.googleauthorHye-Jeong Lee-
dc.contributor.googleauthorYoung Jin Kim-
dc.contributor.googleauthorByoung Wook Choi-
dc.identifier.doi10.3349/ymj.2016.57.5.1243-
dc.contributor.localIdA04059-
dc.contributor.localIdA04370-
dc.contributor.localIdA04422-
dc.contributor.localIdA01892-
dc.contributor.localIdA03093-
dc.contributor.localIdA03320-
dc.contributor.localIdA03361-
dc.contributor.localIdA00727-
dc.relation.journalcodeJ02813-
dc.identifier.eissn1976-2437-
dc.identifier.pmid27401658-
dc.subject.keywordFine needle aspiration-
dc.subject.keywordlung cancer-
dc.subject.keywordpositron-emission tomography-
dc.contributor.alternativeNameKim, Young Jin-
dc.contributor.alternativeNameChoi, Byoung Wook-
dc.contributor.alternativeNameHur, Jin-
dc.contributor.alternativeNameHong, Yoo Jin-
dc.contributor.alternativeNameSuh, Young Joo-
dc.contributor.alternativeNameLee, Jae Hoon-
dc.contributor.alternativeNameLee, Hye Jeong-
dc.contributor.alternativeNameIm, Dong Jin-
dc.contributor.affiliatedAuthorChoi, Byoung Wook-
dc.contributor.affiliatedAuthorHur, Jin-
dc.contributor.affiliatedAuthorHong, Yoo Jin-
dc.contributor.affiliatedAuthorSuh, Young Joo-
dc.contributor.affiliatedAuthorLee, Jae Hoon-
dc.contributor.affiliatedAuthorLee, Hye Jeong-
dc.contributor.affiliatedAuthorIm, Dong Jin-
dc.contributor.affiliatedAuthorKim, Young Jin-
dc.citation.volume57-
dc.citation.number5-
dc.citation.startPage1243-
dc.citation.endPage1251-
dc.identifier.bibliographicCitationYONSEI MEDICAL JOURNAL, Vol.57(5) : 1243-1251, 2016-
dc.date.modified2017-10-24-
dc.identifier.rimsid45822-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Nuclear Medicine (핵의학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.