Abstract
Esophageal leiomyoma derived from the muscularis mucosae (MM) is a rare condition, and the optimal modality for diagnosis and treatment is controversial. Endoscopic ultrasonography can provide an accurate image of esophageal layer structure, providing information on lesion suitability for potential endoscopic therapy. We attempted to investigate the diagnostic value of a transendoscopic balloon-tipped miniature ultrasonic endoprobe for small esophageal leiomyomas derived from MM. We resected 7 small esophageal leiomyomas derived from MM by endoscopic mucosal resection (EMR), all of which were diagnosed by a balloon-tipped endoprobe. The endosonographic and pathologic features of 7 cases of small esophageal leiomyomas derived from MM were compared. The balloon-tipped endoprobe clearly showed all 7 small esophageal leiomyomas derived from MM, even those under 5 mm in size (smallest lesion, 3.0 mm). The endosonographic characteristics of small esophageal leiomyomas derived from MM were a hypoechoic mass with smooth, regular, and a well-defined outer margin and homogenous inner echogram arising from the second hypoechoic layer. Complete resections were possible in all 7 cases by EMR without any complications. Tumor size was 3.0 - 13.5 mm (mean 7.8 mm) in maximum diameter. In all cases, endosonographic findings by endoprobe were exactly concordant with pathologic finding in determining the tumors depth in the esophageal wall, tissue origin and characteristics, growth pattern, and size. We detail the balloon-tipped endoprobe is a simple, convenient, and very useful in making accurate diagnosis of small esophageal leiomyomas derived from the MM and the appropriate applications of EMR.
Files in This Item:
T200501171.pdf Download
DOI
OAK-2005-05645
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Paik, Yong Han(백용한)
Lee, Kwan Sik(이관식) ORCID logo https://orcid.org/0000-0002-3672-1198
Lee, Dong Ki(이동기) ORCID logo https://orcid.org/0000-0002-0048-9112
Lee, Sang In(이상인)
Lee, Se Joon(이세준) ORCID logo https://orcid.org/0000-0002-2695-2670
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/151376
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links