195 511

Cited 4 times in

Comparison of Unmonochromatized Synchrotron Radiation and Conventional X-rays in the Imaging of Mammographic Phantom and Human Breast Specimens: A Preliminary Result

DC Field Value Language
dc.contributor.author김은경-
dc.contributor.author김희중-
dc.contributor.author유형식-
dc.contributor.author정해조-
dc.date.accessioned2017-05-04T07:29:05Z-
dc.date.available2017-05-04T07:29:05Z-
dc.date.issued2005-
dc.identifier.issn0513-5796-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/147357-
dc.description.abstractA simple imaging setup based on the principle of coherence-based contrast X-ray imaging with unmonochromatized synchrotron radiation was used for studying mammographic phantom and human breast specimens. The use of unmonochromatized synchrotron radiation simplifies the instrumentation, decreases the cost and makes the procedure simpler and potentially more suitable for clinical applications. The imaging systems consisted of changeable silicon wafer attenuators, a tungsten slit system, a CdWO4 scintillator screen, a CCD (Charge Coupled Device) camera coupled to optical magnification lenses, and a personal computer. In preliminary studies, a spatial resolution test pattern and glass capillary filled with air bubbles were imaged to evaluate the resOolution characteristics and coherence-based contrast enhancement. Both the spatial resolution and image quality of the proposed system were compared with those of a conventional mammography system in order to establish the characteristic advantages of this approach. The images obtained with the proposed system showed a resolution of at least 25 µm on the test pattern with much better contrast, while the images of the capillary filled with air bubbles revealed coherence-based edge enhancement. This result shows that the coherence-based contrast imaging system, which emphasizes the refraction effect from the edge of materials of different refractive indexes, is applicable to imaging studies in fundamental medicine and biology, although further research works will be required before it can be used for clinical applications.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageEnglish-
dc.publisherYonsei University-
dc.relation.isPartOfYONSEI MEDICAL JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHBreast Diseases/diagnostic imaging*-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHMammography/instrumentation*-
dc.subject.MESHMammography/methods*-
dc.subject.MESHPhantoms, Imaging*-
dc.subject.MESHPilot Projects-
dc.subject.MESHSynchrotrons*-
dc.subject.MESHX-Rays-
dc.titleComparison of Unmonochromatized Synchrotron Radiation and Conventional X-rays in the Imaging of Mammographic Phantom and Human Breast Specimens: A Preliminary Result-
dc.typeArticle-
dc.publisher.locationKorea (South)-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학교실)-
dc.contributor.departmentDept. of Radiology (영상의학교실)-
dc.contributor.departmentDept. of Radiology (영상의학교실)-
dc.contributor.departmentDept. of Radiology (영상의학교실)-
dc.contributor.googleauthorHaijo Jung-
dc.contributor.googleauthorHee-Joung Kim-
dc.contributor.googleauthorEun-Kyung Kim-
dc.contributor.googleauthorJin-O Hong-
dc.contributor.googleauthorJung Ho Je-
dc.contributor.googleauthorYeukuang Hwu-
dc.contributor.googleauthorWen-Li Tsai-
dc.contributor.googleauthorGiorgio Magaritondo-
dc.contributor.googleauthorHyung-Sik Yoo-
dc.identifier.doi10.3349/ymj.2005.46.1.95-
dc.contributor.localIdA00801-
dc.contributor.localIdA01224-
dc.contributor.localIdA02533-
dc.contributor.localIdA03761-
dc.relation.journalcodeJ02813-
dc.identifier.eissn1976-2437-
dc.identifier.pmid15744811-
dc.subject.keywordSynchrotron radiation-
dc.subject.keywordmammography-
dc.contributor.alternativeNameKim, Eun Kyung-
dc.contributor.alternativeNameKim, Hee Joung-
dc.contributor.alternativeNameYoo, Hyung Sik-
dc.contributor.alternativeNameJeong, Hai Jo-
dc.citation.volume46-
dc.citation.number1-
dc.citation.startPage95-
dc.citation.endPage103-
dc.identifier.bibliographicCitationYONSEI MEDICAL JOURNAL, Vol.46(1) : 95-103, 2005-
dc.date.modified2017-05-04-
dc.identifier.rimsid48529-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.