Cited 23 times in
Added value of cardiac computed tomography for evaluation of mechanical aortic valve: Emphasis on evaluation of pannus with surgical findings as standard reference.
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김영진 | - |
dc.contributor.author | 장수연 | - |
dc.contributor.author | 최병욱 | - |
dc.contributor.author | 허진 | - |
dc.contributor.author | 홍그루 | - |
dc.contributor.author | 홍유진 | - |
dc.contributor.author | 서영주 | - |
dc.contributor.author | 심지영 | - |
dc.contributor.author | 이삭 | - |
dc.contributor.author | 이혜정 | - |
dc.contributor.author | 임동진 | - |
dc.contributor.author | 장병철 | - |
dc.date.accessioned | 2017-02-24T11:41:42Z | - |
dc.date.available | 2017-02-24T11:41:42Z | - |
dc.date.issued | 2016 | - |
dc.identifier.issn | 0167-5273 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/146837 | - |
dc.description.abstract | BACKGROUND: The added value of cardiac computed tomography (CT) with transesophageal echocardiography (TEE) for evaluating mechanical aortic valve (AV) dysfunction has not yet been investigated. The purposes of this study were to investigate the added value of cardiac CT for evaluation of mechanical AVs and diagnoses of pannus compared to TEE, with surgical findings of redo-aortic valve replacement (AVR) used as a standard reference. METHODS: 25 patients who underwent redo-AVR due to mechanical AV dysfunction and cardiac CT before redo-AVR were included. The presence of pannus, encroachment ratio by pannus, and limitation of motion (LOM) were evaluated on CT. The diagnostic performance of pannus detection was compared using TEE, CT, and CT+TEE, with surgical findings as a standard reference. The added value of CT for diagnosing the cause of mechanical AV dysfunction was assessed compared to TTE+TEE. RESULTS: In two patients, CT analysis was not feasible due to severe metallic artifacts. On CT, pannus and LOM were found in 100% (23/23) and 60.9% (14/23). TEE identified pannus in 48.0% of patients (12/25). CT, TEE, and CT+TEE correctly identified pannus with sensitivity of 92.0%, 48.0%, and 92.0%, respectively (P=0.002 for CT vs. TEE). In 11 of 13 cases (84.6%) with inconclusive or negative TEE results for pannus, CT detected the pannus. Among 13 inconclusive cases of TTE+TEE for the cause of mechanical AV dysfunction, CT suggested 6 prosthetic valve obstruction (PVO) by pannus, 4 low-flow low-gradient PVO, and one LOM without significant PVO. CONCLUSIONS: Cardiac CT showed added diagnostic value with TEE in the detection of pannus as the cause of mechanical AV dysfunction. | - |
dc.description.statementOfResponsibility | restriction | - |
dc.format.extent | 454~460 | - |
dc.language | English | - |
dc.publisher | Elsevier | - |
dc.relation.isPartOf | INTERNATIONAL JOURNAL OF CARDIOLOGY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Aortic Valve/diagnostic imaging* | - |
dc.subject.MESH | Aortic Valve/surgery | - |
dc.subject.MESH | Echocardiography, Transesophageal | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Heart Valve Diseases/diagnostic imaging* | - |
dc.subject.MESH | Heart Valve Diseases/surgery | - |
dc.subject.MESH | Heart Valve Prosthesis/adverse effects* | - |
dc.subject.MESH | Heart Valve Prosthesis Implantation | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Multimodal Imaging/methods* | - |
dc.subject.MESH | Reoperation | - |
dc.subject.MESH | Sensitivity and Specificity | - |
dc.subject.MESH | Tomography, X-Ray Computed | - |
dc.title | Added value of cardiac computed tomography for evaluation of mechanical aortic valve: Emphasis on evaluation of pannus with surgical findings as standard reference. | - |
dc.type | Article | - |
dc.publisher.location | Netherlands | - |
dc.contributor.college | College of Medicine | - |
dc.contributor.department | Dept. of Radiology | - |
dc.contributor.googleauthor | Young Joo Suh | - |
dc.contributor.googleauthor | Sak Lee | - |
dc.contributor.googleauthor | Dong Jin Im | - |
dc.contributor.googleauthor | Suyon Chang | - |
dc.contributor.googleauthor | Yoo Jin Hong | - |
dc.contributor.googleauthor | Hye-Jeong Lee | - |
dc.contributor.googleauthor | Jin Hur | - |
dc.contributor.googleauthor | Byoung Wook Choi | - |
dc.contributor.googleauthor | Byung-Chul Chang | - |
dc.contributor.googleauthor | Chi Young Shim | - |
dc.contributor.googleauthor | Geu-Ru Hong | - |
dc.contributor.googleauthor | Young Jin Kim | - |
dc.identifier.doi | 10.1016/j.ijcard.2016.04.011 | - |
dc.contributor.localId | A00727 | - |
dc.contributor.localId | A03444 | - |
dc.contributor.localId | A04059 | - |
dc.contributor.localId | A04370 | - |
dc.contributor.localId | A04386 | - |
dc.contributor.localId | A04422 | - |
dc.contributor.localId | A01892 | - |
dc.contributor.localId | A02213 | - |
dc.contributor.localId | A02807 | - |
dc.contributor.localId | A03320 | - |
dc.contributor.localId | A03361 | - |
dc.contributor.localId | A03430 | - |
dc.relation.journalcode | J01093 | - |
dc.identifier.eissn | 1874-1754 | - |
dc.identifier.pmid | 27096962 | - |
dc.identifier.url | http://www.sciencedirect.com/science/article/pii/S0167527316306866 | - |
dc.subject.keyword | Aortic valve replacement | - |
dc.subject.keyword | Computed tomography | - |
dc.subject.keyword | Mechanical valve | - |
dc.subject.keyword | Pannus formation | - |
dc.contributor.alternativeName | Kim, Young Jin | - |
dc.contributor.alternativeName | Chang, Su Yon | - |
dc.contributor.alternativeName | Choi, Byoung Wook | - |
dc.contributor.alternativeName | Hur, Jin | - |
dc.contributor.alternativeName | Hong, Geu Ru | - |
dc.contributor.alternativeName | Hong, Yoo Jin | - |
dc.contributor.alternativeName | Suh, Young Joo | - |
dc.contributor.alternativeName | Shim, Chi Young | - |
dc.contributor.alternativeName | Lee, Sak | - |
dc.contributor.alternativeName | Lee, Hye Jeong | - |
dc.contributor.alternativeName | Im, Dong Jin | - |
dc.contributor.alternativeName | Chang, Byung Chul | - |
dc.contributor.affiliatedAuthor | Kim, Young Jin | - |
dc.contributor.affiliatedAuthor | Chang, Su Yon | - |
dc.contributor.affiliatedAuthor | Choi, Byoung Wook | - |
dc.contributor.affiliatedAuthor | Hur, Jin | - |
dc.contributor.affiliatedAuthor | Hong, Geu Ru | - |
dc.contributor.affiliatedAuthor | Hong, Yoo Jin | - |
dc.contributor.affiliatedAuthor | Suh, Young Joo | - |
dc.contributor.affiliatedAuthor | Shim, Chi Young | - |
dc.contributor.affiliatedAuthor | Lee, Sak | - |
dc.contributor.affiliatedAuthor | Lee, Hye Jeong | - |
dc.contributor.affiliatedAuthor | Im, Dong Jin | - |
dc.contributor.affiliatedAuthor | Chang, Byung Chul | - |
dc.citation.volume | 214 | - |
dc.citation.startPage | 454 | - |
dc.citation.endPage | 460 | - |
dc.identifier.bibliographicCitation | INTERNATIONAL JOURNAL OF CARDIOLOGY, Vol.214 : 454-460, 2016 | - |