Cited 0 times in
Onyx Embolization for Isolated Type Dural Arteriovenous Fistula Using a Dual-Lumen Balloon Catheter.
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김동익 | - |
dc.contributor.author | 김동준 | - |
dc.contributor.author | 김병문 | - |
dc.contributor.author | 김진우 | - |
dc.contributor.author | 박근영 | - |
dc.date.accessioned | 2017-02-24T11:35:26Z | - |
dc.date.available | 2017-02-24T11:35:26Z | - |
dc.date.issued | 2016 | - |
dc.identifier.issn | 0148-396X | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/146807 | - |
dc.description.abstract | BACKGROUND: Utilization of a dual-lumen balloon may improve Onyx penetration into isolated dural arteriovenous fistulas (i-DAVFs). OBJECTIVE: To compare the results of Onyx embolization using a dual-lumen balloon with those using a non-balloon catheter for i-DAVFs. METHODS: Twenty-nine patients underwent Onyx embolization for i-DAVFs using a non-balloon (n = 14) or a dual-lumen balloon catheter (n = 15). Since its introduction, a dual-lumen balloon catheter has been preferred. We compared the dual-lumen balloon group with the non-balloon catheter group regarding angiographic outcome, treatment-related complications, total procedural time, Onyx injection time, and the number of feeders requiring embolization. RESULTS: The dual-lumen balloon group showed complete occlusion of i-DAVFs in 13 and near-complete in 2 patients, while the non-balloon group showed complete occlusion in 5, near-complete in 5, and incomplete in 4 patients (P < .05). Treatment-related complications occurred in 2 patients: 1 in the non-balloon group and 1 in the dual-lumen balloon group. The mean total procedural time was 62 ± 32 minutes in the dual-lumen balloon and 171 ± 88 minutes in the non-balloon group (P < .05). The mean Onyx injection time was 10 ± 6 minutes in the dual-lumen balloon and 49 ± 32 minutes in the non-balloon group (P < .05). The median number of feeders requiring embolization was 1 (range, 1-3) in the dual-lumen balloon and 2 (range, 1-4) in the non-balloon group (P < .05). CONCLUSION: Utilization of a dual-lumen balloon catheter for Onyx embolization of i-DAVF seemed to significantly increase the immediate complete occlusion rate and decrease total procedural time, Onyx injection time, and number of feeders requiring embolization. | - |
dc.description.statementOfResponsibility | restriction | - |
dc.format.extent | 627~636 | - |
dc.language | English | - |
dc.publisher | Lippincott Williams & Wilkins | - |
dc.relation.isPartOf | NEUROSURGERY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Balloon Embolectomy/methods* | - |
dc.subject.MESH | Catheterization | - |
dc.subject.MESH | Catheters | - |
dc.subject.MESH | Central Nervous System Vascular Malformations/therapy* | - |
dc.subject.MESH | Dimethyl Sulfoxide* | - |
dc.subject.MESH | Embolization, Therapeutic/methods* | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Polyvinyls* | - |
dc.subject.MESH | Retrospective Studies | - |
dc.subject.MESH | Treatment Outcome | - |
dc.title | Onyx Embolization for Isolated Type Dural Arteriovenous Fistula Using a Dual-Lumen Balloon Catheter. | - |
dc.type | Article | - |
dc.publisher.location | United States | - |
dc.contributor.college | College of Medicine | - |
dc.contributor.department | Dept. of Radiology | - |
dc.contributor.googleauthor | Jin Woo Kim | - |
dc.contributor.googleauthor | Byung Moon Kim | - |
dc.contributor.googleauthor | Keun Young Park | - |
dc.contributor.googleauthor | Dong Joon Kim | - |
dc.contributor.googleauthor | Dong Ik Kim | - |
dc.identifier.doi | 10.1227/NEU.0000000000001069 | - |
dc.contributor.localId | A00408 | - |
dc.contributor.localId | A00410 | - |
dc.contributor.localId | A00498 | - |
dc.contributor.localId | A01027 | - |
dc.contributor.localId | A01442 | - |
dc.relation.journalcode | J02366 | - |
dc.identifier.eissn | 1524-4040 | - |
dc.identifier.pmid | 26488328 | - |
dc.identifier.url | http://ovidsp.ovid.com/ovidweb.cgi?T=JS&CSC=Y&NEWS=N&PAGE=fulltext&AN=00006123-201605000-00004&LSLINK=80&D=ovft | - |
dc.subject.keyword | Dual-lumen balloon | - |
dc.subject.keyword | Dural arteriovenous fistula | - |
dc.subject.keyword | Embolization | - |
dc.subject.keyword | Onyx | - |
dc.contributor.alternativeName | Kim, Dong Ik | - |
dc.contributor.alternativeName | Kim, Dong Joon | - |
dc.contributor.alternativeName | Kim, Byung Moon | - |
dc.contributor.alternativeName | Kim, Jin Woo | - |
dc.contributor.alternativeName | Park, Keun Young | - |
dc.contributor.affiliatedAuthor | Kim, Dong Ik | - |
dc.contributor.affiliatedAuthor | Kim, Dong Joon | - |
dc.contributor.affiliatedAuthor | Kim, Byung Moon | - |
dc.contributor.affiliatedAuthor | Kim, Jin Woo | - |
dc.contributor.affiliatedAuthor | Park, Keun Young | - |
dc.citation.volume | 78 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 627 | - |
dc.citation.endPage | 636 | - |
dc.identifier.bibliographicCitation | NEUROSURGERY, Vol.78(5) : 627-636, 2016 | - |
dc.date.modified | 2017-02-24 | - |
dc.identifier.rimsid | 47549 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.