0 555

Cited 57 times in

Clinical accuracy of a new apex locator with an automatic compensation circuit

DC Field Value Language
dc.contributor.author김덕원-
dc.contributor.author이승종-
dc.date.accessioned2016-05-16T11:28:06Z-
dc.date.available2016-05-16T11:28:06Z-
dc.date.issued2002-
dc.identifier.issn0099-2399-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/144616-
dc.description.abstractA new circuit was designed to automatically compensate for measurement errors of an electronic apex locator in various electrolytes. Thirty-one root canals were clinically tested for accuracy. A file was inserted into the canal until the apex signal was obtained, at which point the file was immobilized with glass-ionomer cement. After extraction, the apical area was exposed and the position of the file tip was examined under an operating microscope. Distances from the major foramen and cemento dentinal junction (CDJ) were recorded. The average distance from the major foramen was −0.13 mm with a range of −1.28 mm and +0.46 mm. The average distance in 26 detectable CDJ samples was +0.18 mm with a range of −0.98 mm and +0.65 mm. The measurements, which were within ±0.5 mm, were 94% (29/31) from the major foramen and 92% (24/26) from the CDJ. Measurement consistencies within one SD were 81% for the major foramen and 65% for the CDJ, respectively. Measurements within two SD were 97% for the major foramen and 92% for the CDJ. There were no differences between the smaller (<#25) and larger apical foramens (≥#25) or vital and nonvital pulps.-
dc.description.statementOfResponsibilityopen-
dc.format.extent706~709-
dc.relation.isPartOfJOURNAL OF ENDODONTICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHDental Cementum/anatomy & histology-
dc.subject.MESHDentin/anatomy & histology-
dc.subject.MESHElectric Impedance-
dc.subject.MESHElectrolytes/chemistry-
dc.subject.MESHElectronics/instrumentation-
dc.subject.MESHEquipment Design-
dc.subject.MESHGlass Ionomer Cements/chemistry-
dc.subject.MESHHumans-
dc.subject.MESHHydrogen Peroxide/chemistry-
dc.subject.MESHMaterials Testing-
dc.subject.MESHMicroscopy-
dc.subject.MESHMiddle Aged-
dc.subject.MESHObserver Variation-
dc.subject.MESHOdontometry/instrumentation-
dc.subject.MESHRoot Canal Preparation/instrumentation*-
dc.subject.MESHSodium Chloride/chemistry-
dc.subject.MESHSodium Hypochlorite/chemistry-
dc.subject.MESHStatistics as Topic-
dc.subject.MESHTooth Apex/anatomy & histology*-
dc.subject.MESHTooth, Nonvital/pathology-
dc.titleClinical accuracy of a new apex locator with an automatic compensation circuit-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Medical Engineering (의학공학)-
dc.contributor.googleauthorSeung Jong Lee-
dc.contributor.googleauthorKi Chang Nam-
dc.contributor.googleauthorYoung Joo Kim-
dc.contributor.googleauthorDeok Won Kim-
dc.identifier.doi10.1097/00004770-200210000-00007-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00376-
dc.contributor.localIdA02925-
dc.relation.journalcodeJ01393-
dc.identifier.eissn1878-3554-
dc.identifier.pmid12398169-
dc.identifier.urlhttp://www.sciencedirect.com/science/article/pii/S0099239905604621-
dc.contributor.alternativeNameKim, Deok Won-
dc.contributor.alternativeNameLee, Seung Jong-
dc.contributor.affiliatedAuthorKim, Deok Won-
dc.contributor.affiliatedAuthorLee, Seung Jong-
dc.rights.accessRightsnot free-
dc.citation.volume28-
dc.citation.number10-
dc.citation.startPage706-
dc.citation.endPage709-
dc.identifier.bibliographicCitationJOURNAL OF ENDODONTICS, Vol.28(10) : 706-709, 2002-
dc.identifier.rimsid51301-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Medical Engineering (의학공학교실) > 1. Journal Papers
2. College of Dentistry (치과대학) > Dept. of Conservative Dentistry (보존과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.