269 588

Cited 0 times in

Tagline 간격의 조절을 통한 SPAMM 영상에서의 tagging 대조도 대 잡음비의 변화

DC Field Value Language
dc.contributor.author최규옥-
dc.date.accessioned2016-05-16T11:14:41Z-
dc.date.available2016-05-16T11:14:41Z-
dc.date.issued2002-
dc.identifier.issn1226-5829-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/144115-
dc.description.abstractMyocardial tagging technique such as spatial modulation of magnetization (SPAMM) allows the study of myocardial motion with high accuracy. However, the accuracy of the estimation of tag intersection can be affected by tagline spacing. The aim of this study was to investigate the relationship between tagline spacing of SPAMM image and tagging contrast-to-noise ratio (CNR) in in-vivo study. Two healthy volunteers were undergone electrocardiographically triggered MR imaging with SPAMM-based tagging pulse sequence at a 1.5T MR scanner. Horizontally modulated stripe patterns were imposed with a range from 3.6 to 9.6 mm of tagline spacing. Images of the left ventricle(LV) wall were acquired at the mid-ventricle level during cardiac cycle with FE-EPI (TR/TE = 5.8/2.2 msec, FA= 10o. Tagging CNR for each image was calculated with a software which developed in our group. During contraction, tagging CNR was more rapidly decreased in case of narrow tagline spacing than in case of wide tagline spacing. In the same heart phase, CNR was increased corresponding with tagline spacing. Especially, at the fully contracted heart phase, CNR was more rapidly increased than the other heart phases as a function of tagline spacing. The results indicated that the optimization of tagline spacing provides better tagging CNR in order to analyze the myocardial motion more accurately.-
dc.description.statementOfResponsibilityopen-
dc.format.extent224~228-
dc.relation.isPartOfKorean Journal of Medical Physics (의학물리)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleTagline 간격의 조절을 통한 SPAMM 영상에서의 tagging 대조도 대 잡음비의 변화-
dc.title.alternativeThe Variation of Tagging Contrast-to-Noise Radio (CNR) of SPAMM Image by Modulation of Tagline Spacing-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학)-
dc.contributor.googleauthor강원석-
dc.contributor.googleauthor최병욱-
dc.contributor.googleauthor최규옥-
dc.contributor.googleauthor이상호-
dc.contributor.googleauthor홍순일-
dc.contributor.googleauthor정해조-
dc.contributor.googleauthor김희중-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA04042-
dc.relation.journalcodeJ02057-
dc.subject.keywordMyocardial tagging-
dc.subject.keywordTagline spacing-
dc.subject.keywordSPAMM-
dc.subject.keywordCNR-
dc.contributor.alternativeNameChoe, Kyu Ok-
dc.contributor.affiliatedAuthorChoe, Kyu Ok-
dc.rights.accessRightsfree-
dc.citation.volume13-
dc.citation.number4-
dc.citation.startPage224-
dc.citation.endPage228-
dc.identifier.bibliographicCitationKorean Journal of Medical Physics (의학물리), Vol.13(4) : 224-228, 2002-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.