844 776

Cited 0 times in

상층두께와 관심영역의 크기 변화가 CT번호에 미치는 영향

DC Field Value Language
dc.contributor.author김기덕-
dc.contributor.author박창서-
dc.date.accessioned2016-02-19T11:08:56Z-
dc.date.available2016-02-19T11:08:56Z-
dc.date.issued2001-
dc.identifier.issn1229-8212-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/142505-
dc.description.abstractPurpose: To evaluate the effect of the slice thickness and the size of region of interest (ROI) on CT number using quantitative CT phantom Materials and Methods: The phantom containing 150 mg/cc, 75 mg/cc and 0 mg/cc calcium hydroxyapatite was scanned with 1, 3, 5 and 10 mm slice thicknesses by single energy quantitative computed tomography (QCT). CT numbers were measured on center position of the phantom. Shape of ROI was circular and sizes were 1, 3, 5, 11, 16, 21, 26 and 33 mm². ANOVA and Tukey's multiple comparison method were performed for statistical comparison of CT numbers according to different slice thicknesses. Coefficient of variation of CT number measured in each size of ROI was evaluated in same slice thickness. Results : CT numbers had statistically significant difference according to slice thicknesses (p<0.05). As the slice thickness increased, CT number also increased. As the density of phantom became lower and the size of ROI became smaller, the coefficient of variation of CT number increased. When the size of ROI was more than 11 mm² in 1 mm slice thickness, 5 mm² in 3 mm slice thickness and 3 mm² in 5 mm slice thickness, the coefficient of variation became consistent. In 10 mm slice thickness, the size of ROI had little effect on the coefficient of variation. Conclusion: CT number had variation according to the slice thickness and the size of ROI although the object was homogeneous. The slice thickness and the size of ROI are critical factors in precision of the CT number measurements.-
dc.description.statementOfResponsibilityopen-
dc.format.extent85~91-
dc.languageKorean-
dc.publisher대한구강악안면방사선학회-
dc.relation.isPartOfKorean Journal of Oral and Maxillofacial Radiology (대한구강악안면방사선학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title상층두께와 관심영역의 크기 변화가 CT번호에 미치는 영향-
dc.title.alternativeEffect of the slice thickness and the size of region of interest on CT number-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Oral and Maxillofacial Radiology (구강악안면방사선과학)-
dc.contributor.googleauthor이지연-
dc.contributor.googleauthor김기덕-
dc.contributor.googleauthor박창서-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00332-
dc.contributor.localIdA01715-
dc.relation.journalcodeJ02085-
dc.subject.keywordtomography-
dc.subject.keywordX-ray computed-
dc.subject.keywordevaluation-
dc.subject.keywordquantitave-
dc.subject.keywordphantoms-
dc.subject.keywordimaging-
dc.contributor.alternativeNameKim, Kee Deog-
dc.contributor.alternativeNamePark, Chang Seo-
dc.contributor.affiliatedAuthorKim, Kee Deog-
dc.contributor.affiliatedAuthorPark, Chang Seo-
dc.rights.accessRightsfree-
dc.citation.volume31-
dc.citation.number2-
dc.citation.startPage85-
dc.citation.endPage91-
dc.identifier.bibliographicCitationKorean Journal of Oral and Maxillofacial Radiology, Vol.31(2) : 85-91, 2001-
dc.identifier.rimsid31050-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Advanced General Dentistry (통합치의학과) > 1. Journal Papers
2. College of Dentistry (치과대학) > Dept. of Oral and Maxillofacial Radiology (영상치의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.