0 414

Cited 33 times in

Aortic Dissection: Percutaneous Management with a Separating Stent-Graft—Preliminary Results

Authors
 Sung-Gwon Kang  ;  Do Yun Lee  ;  Munehiro Maeda  ;  Eun Sang Kim  ;  Donghoon Choi  ;  Byung-Ok Kim  ;  Hyun Ki Yoon  ;  Kyu Bo Sung  ;  Ho-Young Song 
Citation
 RADIOLOGY, Vol.220(2) : 533-539, 2001 
Journal Title
RADIOLOGY
ISSN
 0033-8419 
Issue Date
2001
MeSH
Adult ; Aged ; Aneurysm, Dissecting/therapy* ; Aortic Aneurysm/therapy* ; Blood Vessel Prosthesis* ; Female ; Follow-Up Studies ; Humans ; Male ; Middle Aged ; Models, Cardiovascular ; Stents*
Abstract
The authors used a separating stent-graft to treat Stanford type B aortic dissection. The separating stent-graft consists of two stents: a stent-graft and an inner bare stent. The separating stent-graft has three parts: a proximal stent, a graft made of synthetic polyester textile fiber, and a distal stent. A 12-F introducing sheath was used. After the separating stent-graft was placed, false-lumen thrombosis was evident in all six patients during a follow-up period of 206 days. The major advantages of this technique are that a cutdown and blood pressure control are not required.
Full Text
http://pubs.rsna.org/doi/abs/10.1148/radiology.220.2.r01au24533
DOI
10.1148/radiology.220.2.r01au24533
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Lee, Do Yun(이도연)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/142490
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.