Cited 7 times in
Detection and Correction of Laterality Errors in Radiology Reports
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 서진석 | - |
dc.contributor.author | 양재문 | - |
dc.contributor.author | 이영한 | - |
dc.date.accessioned | 2016-02-04T11:42:55Z | - |
dc.date.available | 2016-02-04T11:42:55Z | - |
dc.date.issued | 2015 | - |
dc.identifier.issn | 0897-1889 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/141037 | - |
dc.description.abstract | The objectives of the study are to introduce the development of supervising software for double-checking of laterality error in radiology reports and to evaluate the usefulness of detection and correction software by applying it to radiology report systems. An AutoHotkey macro program was applied to the design for double-checking of laterality errors. The software was performed according to the flowchart below: (1) detecting laterality discrepancies between radiologic examination names and the context of the radiology report and (2) providing conditioned discrepancy correction with a pop-up window. The accuracy of the detection was evaluated with 300 radiologic examinations that include the intended discrepancies and concordance of lateralities. The number of detections and corrections were quantified, and the confidence intervals were calculated for accuracy. We also applied this module to previous radiology reports with laterality errors from the radiologic examination database to validate the module. The AutoHotkey-scripted macro program functioned well in the reading workstation, and it was acted successfully as additional software. The detection accuracy was 99.67% (95% CI; 99.01-%) in the 300 radiologic examinations from the radiologic reading session. There was one running failure, caused by a temporary lag in the hospital's computer network, but no failures resulted during the second trial. We found that there were laterality errors in 0.048% (n = 14/29,257) of the examinations from the database. We developed detection and correction software aimed at double-checking for laterality errors. This method can be successfully adopted in any hospital software and is expected to be included for a better radiologic reading environment. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 412~416 | - |
dc.relation.isPartOf | JOURNAL OF DIGITAL IMAGING | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Electronic Health Records/standards* | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Quality Control* | - |
dc.subject.MESH | Radiology Information Systems/standards* | - |
dc.subject.MESH | Reproducibility of Results | - |
dc.subject.MESH | Software Design* | - |
dc.title | Detection and Correction of Laterality Errors in Radiology Reports | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Radiology (영상의학) | - |
dc.contributor.googleauthor | Young Han Lee | - |
dc.contributor.googleauthor | Jaemoon Yang | - |
dc.contributor.googleauthor | Jin Suck Suh | - |
dc.identifier.doi | 10.1007/s10278-015-9772-x | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A02315 | - |
dc.contributor.localId | A01916 | - |
dc.contributor.localId | A02967 | - |
dc.relation.journalcode | J01379 | - |
dc.identifier.eissn | 1618-727X | - |
dc.identifier.pmid | 25712502 | - |
dc.identifier.url | http://link.springer.com/article/10.1007/s10278-015-9772-x | - |
dc.subject.keyword | Quality control | - |
dc.subject.keyword | Radiology reporting | - |
dc.subject.keyword | Radiology workflow | - |
dc.subject.keyword | Reporting | - |
dc.subject.keyword | Laterality error | - |
dc.subject.keyword | Supervising software | - |
dc.contributor.alternativeName | Suh, Jin Suck | - |
dc.contributor.alternativeName | Yang, Jae Moon | - |
dc.contributor.alternativeName | Lee, Young Han | - |
dc.contributor.affiliatedAuthor | Yang, Jae Moon | - |
dc.contributor.affiliatedAuthor | Suh, Jin Suck | - |
dc.contributor.affiliatedAuthor | Lee, Young Han | - |
dc.rights.accessRights | not free | - |
dc.citation.volume | 28 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 412 | - |
dc.citation.endPage | 416 | - |
dc.identifier.bibliographicCitation | JOURNAL OF DIGITAL IMAGING, Vol.28(4) : 412-416, 2015 | - |
dc.identifier.rimsid | 30471 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.