495 797

Cited 0 times in

각막굴절교정학 렌즈를 이용한 소아 근시 교정 실패원인 분석

Other Titles
 Analysis of the Cause of Failure in the Correction of Childhood Myopia Using Orthokeratologic Lenses 
Authors
 이성훈  ;  이동호  ;  이형근 
Citation
 JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.56(3) : 317-322, 2015 
Journal Title
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY(대한안과학회지)
ISSN
 0378-6471 
Issue Date
2015
Keywords
Childhood myopia ; Odds of failure ; Orthokeratologic lens ; Spherical diopter
Abstract
Purpose: To investigate the cause of failure in the correction of childhood myopia using orthokeratologic (Ortho-K) lenses.
Methods: The failure group was 29 patients who stopped wearing the lenses for various reasons, while the success group was 29 patients who bought lenses more than twiceand wore them for two years and more. Statistical analyses were performed to identify significant differences between the groups.
Results: Among the failure group, failure to continuously wear the Ortho-K lenses was attributed to undercorrection (19 patients), corneal erosion (2 patients), and sleep disorders (1 patient). Initial spherical diopter and initial spherical equivalent diopter showed statistical diffence between the success group and failure group. Of these two factors, as the initial spherical equivalent diopter increased, the chance of failure to use Ortho-K lens increased. According to a logistic multiple regression analysis, the odds of failure of using Ortho-K lens increased by 1.59 when the initial spherical diopter increased by 1. If the absolute value of the initial spherical diopter was over 6.24, the chance of failure increased by 80%.
Conclusions: The failure of continuously wearing Ortho-K lenses due to undercorrection was found to be the major cause of failure in the correction of childhood myopia. The initial spherical diopter and initial spherical equivalent diopter were significant factors influencing the undercorrection. From these results, we predict that the odds of failure of continuously wearing Ortho-K lenses increases along with increases in the initial spherical diopter. In conclusion, clinicians should be warned concerning the odds of failure due to low initial spherical diopter.
Files in This Item:
T201501977.pdf Download
DOI
10.3341/jkos.2015.56.3.317
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers
Yonsei Authors
Lee, Hyung Keun(이형근) ORCID logo https://orcid.org/0000-0002-1123-2136
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/140403
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links