Computed tomographic beam-hardening artefacts: mathematical characterization and analysis.

DC Field Value Language
dc.contributor.author정용은-
dc.date.accessioned2016-02-04T11:16:40Z-
dc.date.available2016-02-04T11:16:40Z-
dc.date.issued2015-
dc.identifier.issn1364-503X-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/140066-
dc.description.abstractThis paper presents a mathematical characterization and analysis of beam-hardening artefacts in X-ray computed tomography (CT). In the field of dental and medical radiography, metal artefact reduction in CT is becoming increasingly important as artificial prostheses and metallic implants become more widespread in ageing populations. Metal artefacts are mainly caused by the beam-hardening of polychromatic X-ray photon beams, which causes mismatch between the actual sinogram data and the data model being the Radon transform of the unknown attenuation distribution in the CT reconstruction algorithm. We investigate the beam-hardening factor through a mathematical analysis of the discrepancy between the data and the Radon transform of the attenuation distribution at a fixed energy level. Separation of cupping artefacts from beam-hardening artefacts allows causes and effects of streaking artefacts to be analysed. Various computer simulations and experiments are performed to support our mathematical analysis.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfPHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleComputed tomographic beam-hardening artefacts: mathematical characterization and analysis.-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학)-
dc.contributor.googleauthorHyoung Suk Park-
dc.contributor.googleauthorYong Eun Chung-
dc.contributor.googleauthorJin Keun Seo-
dc.identifier.doi10.1098/rsta.2014.0388-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA03662-
dc.relation.journalcodeJ02513-
dc.identifier.eissn1471-2962-
dc.identifier.pmid25939628-
dc.identifier.urlhttp://rsta.royalsocietypublishing.org/content/373/2043/20140388.abstract-
dc.subject.keywordRadon transform-
dc.subject.keywordbeam-hardening artefacts-
dc.subject.keywordcomputerized tomography-
dc.subject.keywordwavefront set-
dc.contributor.alternativeNameChung, Yong Eun-
dc.contributor.affiliatedAuthorChung, Yong Eun-
dc.rights.accessRightsnot free-
dc.citation.volume373-
dc.citation.number2043-
dc.citation.startPage20140388-
dc.identifier.bibliographicCitationPHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, Vol.373(2043) : 20140388, 2015-
dc.identifier.rimsid45609-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode