Cited 8 times in
Usefulness of thin-section single-shot turbo spin echo with half-Fourier acquisition in evaluation of local invasion of lung cancer
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김영진 | - |
dc.contributor.author | 이혜정 | - |
dc.contributor.author | 장수연 | - |
dc.contributor.author | 최병욱 | - |
dc.contributor.author | 허진 | - |
dc.contributor.author | 홍새롬 | - |
dc.contributor.author | 홍유진 | - |
dc.date.accessioned | 2016-02-04T11:08:55Z | - |
dc.date.available | 2016-02-04T11:08:55Z | - |
dc.date.issued | 2015 | - |
dc.identifier.issn | 1053-1807 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/139773 | - |
dc.description.abstract | PURPOSE: To evaluate the usefulness of thin-section single-shot turbo spin echo with half-Fourier acquisition (SS-TSE-HF) alone for evaluation of local invasion of lung cancer. MATERIALS AND METHODS: Our Institutional Review Board approved this retrospective study. Thirty-six patients with lung cancer who underwent magnetic resonance imaging (MRI) for evaluation of local invasion followed by curative surgery from July 2008 to June 2012 were enrolled in this study. Two reviewers independently and blindly reviewed computed tomography (CT) and MRI (thin-section SS-TSE-HF and conventional MRI, which consisted of conventional axial SS-TSE-HF, dynamic MRI with respiratory and/or cardiac cine, and T1 -weighted high-resolution isotropic volume examination [THRIVE]) for the presence of local invasion. Diagnostic performances were evaluated using gross surgical findings and pathological results as a standard reference. RESULTS: The overall diagnostic performance for detecting local invasion of lung cancer between the two reviewers were as follows: specificity and accuracy of thin-section SS-TSE-HF (89.0% and 87.5%) were significantly higher than those of CT (25.6% and 46.9%, P < 0.001 for both) or conventional MRI (61.0% and 69.5%, P < 0.001 and P = 0.008, respectively). Sensitivity was 84.8% for thin-section SS-TSE-HF with the same value for CT (P = 0.246) and conventional MRI (P = 0.209). CONCLUSION: Thin-section SS-TSE-HF sequence alone without any contrast agent demonstrated a relatively high diagnostic performance in evaluation of local invasion of lung cancer. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 747~754 | - |
dc.relation.isPartOf | JOURNAL OF MAGNETIC RESONANCE IMAGING | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Aged, 80 and over | - |
dc.subject.MESH | Artifacts | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Fourier Analysis* | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Image Processing, Computer-Assisted/methods* | - |
dc.subject.MESH | Lung/diagnostic imaging | - |
dc.subject.MESH | Lung/pathology | - |
dc.subject.MESH | Lung Neoplasms/diagnostic imaging | - |
dc.subject.MESH | Lung Neoplasms/pathology* | - |
dc.subject.MESH | Magnetic Resonance Imaging/methods* | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Observer Variation | - |
dc.subject.MESH | Reproducibility of Results | - |
dc.subject.MESH | Retrospective Studies | - |
dc.subject.MESH | Sensitivity and Specificity | - |
dc.subject.MESH | Tomography, X-Ray Computed | - |
dc.title | Usefulness of thin-section single-shot turbo spin echo with half-Fourier acquisition in evaluation of local invasion of lung cancer | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Radiology (영상의학) | - |
dc.contributor.googleauthor | Suyon Chang | - |
dc.contributor.googleauthor | Sae Rom Hong | - |
dc.contributor.googleauthor | Young Jin Kim | - |
dc.contributor.googleauthor | Yoo Jin Hong | - |
dc.contributor.googleauthor | Jin Hur | - |
dc.contributor.googleauthor | Byoung Wook Choi | - |
dc.contributor.googleauthor | Hye Jeong Lee | - |
dc.identifier.doi | 10.1002/jmri.24587 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00727 | - |
dc.contributor.localId | A03320 | - |
dc.contributor.localId | A03444 | - |
dc.contributor.localId | A04059 | - |
dc.contributor.localId | A04370 | - |
dc.contributor.localId | A04396 | - |
dc.contributor.localId | A04422 | - |
dc.relation.journalcode | J01567 | - |
dc.identifier.eissn | 1522-2586 | - |
dc.identifier.pmid | 24500856 | - |
dc.identifier.url | http://onlinelibrary.wiley.com/doi/10.1002/jmri.24587/abstract | - |
dc.subject.keyword | HASTE | - |
dc.subject.keyword | local invasion | - |
dc.subject.keyword | lung cancer | - |
dc.subject.keyword | single-shot turbo spin echo with half-Fourier acquisition | - |
dc.subject.keyword | thin-section | - |
dc.contributor.alternativeName | Kim, Young Jin | - |
dc.contributor.alternativeName | Lee, Hye Jeong | - |
dc.contributor.alternativeName | Chang, Su Yon | - |
dc.contributor.alternativeName | Choi, Byoung Wook | - |
dc.contributor.alternativeName | Hur, Jin | - |
dc.contributor.alternativeName | Hong, Sae Rom | - |
dc.contributor.alternativeName | Hong, Yoo Jin | - |
dc.contributor.affiliatedAuthor | Kim, Young Jin | - |
dc.contributor.affiliatedAuthor | Lee, Hye Jeong | - |
dc.contributor.affiliatedAuthor | Chang, Su Yon | - |
dc.contributor.affiliatedAuthor | Choi, Byoung Wook | - |
dc.contributor.affiliatedAuthor | Hur, Jin | - |
dc.contributor.affiliatedAuthor | Hong, Sae Rom | - |
dc.contributor.affiliatedAuthor | Hong, Yoo Jin | - |
dc.rights.accessRights | not free | - |
dc.citation.volume | 41 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 747 | - |
dc.citation.endPage | 754 | - |
dc.identifier.bibliographicCitation | JOURNAL OF MAGNETIC RESONANCE IMAGING, Vol.41(3) : 747-754, 2015 | - |