0 664

Cited 10 times in

New predictive equation for lung volume using chest computed tomography for size matching in lung transplantation

DC Field Value Language
dc.contributor.author김태훈-
dc.contributor.author박철환-
dc.contributor.author백효채-
dc.contributor.author이성수-
dc.contributor.author함석진-
dc.date.accessioned2016-02-04T11:05:38Z-
dc.date.available2016-02-04T11:05:38Z-
dc.date.issued2015-
dc.identifier.issn0041-1345-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/139648-
dc.description.abstractPURPOSE: Lung size matching is important in lung transplantation (LT). With advances in computed tomography (CT) technology, multidetector row CT can accurately measure the thoracic cage and lung volumes. The objective of this study was to generate a new regression equation using demographic data based on the measured CT lung volume in a healthy population to predict the CT lung volume of the donor in LT size matching. MATERIALS AND METHODS: The medical records of healthy subjects who underwent chest CT scans to screen for lung cancer were retrospectively reviewed. CT lung volume was semi-automatically measured using a threshold-based auto-segmentation technique. New regression equations for CT lung volume were generated by multiple linear regression analysis using demographic data including height (H, cm), weight (W, kg), and age (A, years). The percentage error rate (%) of the equations were calculated as ([Estimated CT lung volume--Measured CT lung volume]/Measured CT lung volume × 100). A percentage error rate within ± 20% was considered acceptable. RESULTS: A total of 141 men aged 27 to 55 years (mean, 46.7 ± 6.2 years) and 128 women aged 20 to 55 years (mean, 45.4 ± 7.2 years) were enrolled. The final regression equations for CT lung volume were (-5.890 + 0.067 H - 0.030 W + 0.020 A) in men and (-6.698 + 0.072 H - 0.024 W) in women. The mean absolute error rate was 10.9 ± 9.0% and 11.0 ± 8.5% in men and women, respectively. Percentage error rates were within ± 20% in 121 of 141 (85.8%) men and 113 of 128 (88.3%) women. CONCLUSION: These equations could predict the CT lung volume of healthy subjects using demographic data. Using these equations, the predicted CT lung volume of donors could be matched to the measured CT lung volume of recipients in lung transplantation.-
dc.description.statementOfResponsibilityopen-
dc.format.extent498~503-
dc.relation.isPartOfTRANSPLANTATION PROCEEDINGS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHAge Factors-
dc.subject.MESHAlgorithms*-
dc.subject.MESHBody Height-
dc.subject.MESHBody Weight-
dc.subject.MESHDonor Selection*-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHLinear Models-
dc.subject.MESHLung/anatomy & histology-
dc.subject.MESHLung/diagnostic imaging*-
dc.subject.MESHLung Transplantation*-
dc.subject.MESHLung Volume Measurements/methods-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHMultidetector Computed Tomography*-
dc.subject.MESHOrgan Size-
dc.subject.MESHPredictive Value of Tests-
dc.subject.MESHRetrospective Studies-
dc.subject.MESHSex Factors-
dc.subject.MESHYoung Adult-
dc.titleNew predictive equation for lung volume using chest computed tomography for size matching in lung transplantation-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Thoracic & Cardiovascular Surgery (흉부외과학)-
dc.contributor.googleauthorC.H. Park-
dc.contributor.googleauthorT.H. Kim-
dc.contributor.googleauthorS. Lee-
dc.contributor.googleauthorH.C. Paik-
dc.contributor.googleauthorS.J. Haam-
dc.identifier.doi10.1016/j.transproceed.2014.12.025-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01086-
dc.contributor.localIdA01722-
dc.contributor.localIdA01846-
dc.contributor.localIdA02866-
dc.contributor.localIdA04335-
dc.relation.journalcodeJ02755-
dc.identifier.eissn1873-2623-
dc.identifier.pmid25769597-
dc.identifier.urlhttp://www.sciencedirect.com/science/article/pii/S0041134515000135-
dc.contributor.alternativeNameKim, Tae Hoon-
dc.contributor.alternativeNamePark, Chul Hwan-
dc.contributor.alternativeNamePaik, Hyo Chae-
dc.contributor.alternativeNameLee, Sung Soo-
dc.contributor.alternativeNameHaam, Seok Jin-
dc.contributor.affiliatedAuthorKim, Tae Hoon-
dc.contributor.affiliatedAuthorPark, Chul Hwan-
dc.contributor.affiliatedAuthorPaik, Hyo Chae-
dc.contributor.affiliatedAuthorLee, Sung Soo-
dc.contributor.affiliatedAuthorHaam, Seok Jin-
dc.rights.accessRightsnot free-
dc.citation.volume47-
dc.citation.number2-
dc.citation.startPage498-
dc.citation.endPage503-
dc.identifier.bibliographicCitationTRANSPLANTATION PROCEEDINGS, Vol.47(2) : 498-503, 2015-
dc.identifier.rimsid52381-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Thoracic and Cardiovascular Surgery (흉부외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.