0 627

Cited 41 times in

Photoacoustic imaging of breast microcalcifications: a validation study with 3-dimensional ex vivo data and spectrophotometric measurement.

DC Field Value Language
dc.contributor.author김가람-
dc.contributor.author김은경-
dc.date.accessioned2016-02-04T10:54:53Z-
dc.date.available2016-02-04T10:54:53Z-
dc.date.issued2015-
dc.identifier.issn1864-063X-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/139257-
dc.description.abstractThis paper investigates whether photoacoustic imaging (PAI) can provide the visualization of microcalcifications in breast tissue. For this, the geometrical correlation between the 3-D PA images of breast microcalcifications within ex vivo specimens and the corresponding mammograms was ascertained. Also, the optical absorbance of the calcification compositions (i.e., hydroxyapatite and calcium oxalate) was measured and compared with the PA responses of the microcalcifications. The experimental results demonstrated that the PA images discriminated between the microcalcifications and the surrounding tissue, and their locations in PA images reasonably meshed with those of the microcalcifications appeared in the mammograms. Also, the change in PA signal amplitude along the laser wavelength agreed with the absorbance of hydroxyapatite associated with the relatively high potential of malignant cancers, but not calcium oxalate with only benign cases.-
dc.description.statementOfResponsibilityopen-
dc.format.extent71~80-
dc.relation.isPartOfJOURNAL OF BIOPHOTONICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHBreast/metabolism-
dc.subject.MESHBreast/pathology*-
dc.subject.MESHCalcinosis/diagnosis*-
dc.subject.MESHCalcinosis/diagnostic imaging-
dc.subject.MESHCalcium Oxalate/metabolism-
dc.subject.MESHDurapatite/metabolism-
dc.subject.MESHHumans-
dc.subject.MESHImaging, Three-Dimensional*-
dc.subject.MESHMammography-
dc.subject.MESHPhantoms, Imaging-
dc.subject.MESHPhotoacoustic Techniques*-
dc.subject.MESHSpectrophotometry*-
dc.titlePhotoacoustic imaging of breast microcalcifications: a validation study with 3-dimensional ex vivo data and spectrophotometric measurement.-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학)-
dc.contributor.googleauthorJeeun Kang-
dc.contributor.googleauthorEun-kyung Kim-
dc.contributor.googleauthorGa Ram Kim-
dc.contributor.googleauthorChanghan Yoon-
dc.contributor.googleauthorTai-kyong Song-
dc.contributor.googleauthorJin Ho Chang-
dc.identifier.doi10.1002/jbio.201300100-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00284-
dc.contributor.localIdA00801-
dc.relation.journalcodeJ01271-
dc.identifier.eissn1864-0648-
dc.identifier.pmid23996971-
dc.identifier.urlhttp://onlinelibrary.wiley.com/doi/10.1002/jbio.201300100/abstract-
dc.subject.keywordPhotoacoustic imaging-
dc.subject.keywordbreast cancer screening-
dc.subject.keywordcalcium oxalate-
dc.subject.keywordhydroxyapatite-
dc.subject.keywordmammography-
dc.subject.keywordmicrocalcifications-
dc.subject.keywordultrasonography-
dc.contributor.alternativeNameKim, Ga Ram-
dc.contributor.alternativeNameKim, Eun Kyung-
dc.contributor.affiliatedAuthorKim, Ga Ram-
dc.contributor.affiliatedAuthorKim, Eun-Kyung-
dc.rights.accessRightsnot free-
dc.citation.volume8-
dc.citation.number1~2-
dc.citation.startPage71-
dc.citation.endPage80-
dc.identifier.bibliographicCitationJOURNAL OF BIOPHOTONICS, Vol.8(1~2) : 71-80, 2015-
dc.identifier.rimsid45526-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.