349 666

Cited 11 times in

Ex vivo estimation of photoacoustic imaging for detecting thyroid microcalcifications.

DC Field Value Language
dc.contributor.author강상욱-
dc.contributor.author곽진영-
dc.contributor.author권형주-
dc.contributor.author김은경-
dc.contributor.author정웅윤-
dc.date.accessioned2015-12-28T10:53:01Z-
dc.date.available2015-12-28T10:53:01Z-
dc.date.issued2014-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/138231-
dc.description.abstractBACKGROUND: The aim of this study was to evaluate the diagnostic utility of PAI at detecting thyroid microcalcifications at 700 nm laser wavelengths. METHODS: This study included 36 resected samples in 18 patients. To evaluate the PA manifestation of microcalcifications in PAI, gray level histogram and co-occurrence matrix (COM) texture parameters were extracted from the 3 fixed ROI US and PA images, respectively, per sample. We compared the textural parameters obtained from specimen PAIs between samples with punctate microcalcifications on specimen radiography and those without microcalcifications. RESULTS: On specimen US, the mean value (2748.4 ± 862.5) of samples with microcalcifications on specimen radiography was higher than that (1961.9 ± 780.2) of those without microcalcifications (P = 0.007). However, there were no significant differences in textural parameters obtained from specimen PAIs between samples with punctate microcalcifications on specimen radiography and those without when applying both the mean value of the three slices of thyroid specimens and the value of the thyroid specimen slice which had the highest value of the mean values in specimen US. CONCLUSION: PAI did not show significant PA contrast on thyroid microcalcifications indicating that the experimental setup and protocols should be enhanced, e.g., method of complete blood rejection from ex vivo specimens, the multi-wavelength spectroscopic PA imaging method which can solely extract the PA signal from microcalcifications even with high spectral interferences, or PA imaging with narrower slice thickness using 2-dimensional array transducer, etc.-
dc.description.statementOfResponsibilityopen-
dc.format.extente113358-
dc.relation.isPartOfPLOS ONE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHCalcinosis/diagnosis*-
dc.subject.MESHCalcinosis/diagnostic imaging-
dc.subject.MESHDiagnostic Imaging/methods-
dc.subject.MESHElasticity Imaging Techniques/methods*-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHImage Enhancement/methods*-
dc.subject.MESHImage Processing, Computer-Assisted/methods-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHPhotoacoustic Techniques/methods*-
dc.subject.MESHRadiography-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHSensitivity and Specificity-
dc.subject.MESHThyroid Gland/diagnostic imaging-
dc.subject.MESHThyroid Gland/pathology*-
dc.titleEx vivo estimation of photoacoustic imaging for detecting thyroid microcalcifications.-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Surgery (외과학)-
dc.contributor.googleauthorJeeun Kang-
dc.contributor.googleauthorWoong Youn Chung-
dc.contributor.googleauthorSang Wook Kang-
dc.contributor.googleauthorHyeong Ju Kwon-
dc.contributor.googleauthorJaeheung Yoo-
dc.contributor.googleauthorEun Kyung Kim-
dc.contributor.googleauthorJin Ho Chang-
dc.contributor.googleauthorTai kyong Song-
dc.contributor.googleauthorSohee Lee-
dc.contributor.googleauthorJin Young Kwak-
dc.identifier.doi10.1371/journal.pone.0113358-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00032-
dc.contributor.localIdA00182-
dc.contributor.localIdA00264-
dc.contributor.localIdA00801-
dc.contributor.localIdA03674-
dc.relation.journalcodeJ02540-
dc.identifier.eissn1932-6203-
dc.identifier.pmid25415564-
dc.contributor.alternativeNameKang, Sang Wook-
dc.contributor.alternativeNameKwak, Jin Young-
dc.contributor.alternativeNameKwon, Hyeong Ju-
dc.contributor.alternativeNameKim, Eun Kyung-
dc.contributor.alternativeNameChung, Woung Youn-
dc.contributor.affiliatedAuthorKang, Sang Wook-
dc.contributor.affiliatedAuthorKwak, Jin Young-
dc.contributor.affiliatedAuthorKwon, Hyeong Ju-
dc.contributor.affiliatedAuthorKim, Eun-Kyung-
dc.contributor.affiliatedAuthorChung, Woung Youn-
dc.citation.volume9-
dc.citation.number11-
dc.citation.startPagee113358-
dc.identifier.bibliographicCitationPLOS ONE, Vol.9(11) : e113358, 2014-
dc.identifier.rimsid52325-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Pathology (병리학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Surgery (외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.