0 500

Cited 0 times in

The histomorphometric analysis of surface-treated implant with different size of TiO2 Nanotubes on osseointegration in mongrel dog

Other Titles
 잡견에 식립된 서로 다른 직경의 TiO2 나노튜브 표면 처리된 임플란트의 조직계측학적 연구 
Authors
 Jamiyandorj, Otgonbold 
Issue Date
2013
Description
Dept. of Dental Science/박사
Abstract
Implant systems available today present several types of surface treatment with the aim to optimize osseointegration. The purpose of this study was to evaluate surface-treated implant with different size of TiO2 nanotubes on the osseointegration in mongrel dog. In this study, five dogs were selected and a total of 80 titanium implants were placed in both maxilla and mandible. Eight weeks after extraction, 16 internal type implants with different surface treatments were placed for each mongrel dog, having 4 implants at all quadrants. Resorbable blasted media(RBM) surfaced implants were used as a control group and implants which were surface-treated with various diameter of nanotubes (30 nm, 70 nm, 100 nm) were used as experimental groups. The dogs were sacrificed at 4 weeks and 12 weeks after implantation. Removal torque test (removal torque value; RTV) and histomorphometric analysis (Bone-to-Implant contact; BIC, bone volume; BV) were performed, and Kruskall-wallis test was used for statistical analysis. The results from removal torque test were as follows: (RTV; Group Mean SD; 4 weeks: RBM (control)16.92±5.12, 30 nm(Exp 30) 26.18±5.11, 70 nm(Exp 70): 21.78±5.39, 100 nm(Exp 100): 20.30±5.18, 12 weeks; 21.40±9.22, 36.58±5.99, 37.42±9.23, 29.40±2.57). The results from removal torque test did not show statistically significant difference. The results from histomorphometric analysis were as follows: (BIC Group Mean SD; 4 weeks: 31.42±4.67, 28.37±8.69, 27.96±4.78, 35.58±9.36, 12 weeks: 37.53±1.67, 38.44±8.59, 32.38±7.36, 41.51±9.53), (BV Group Mean SD; 4 weeks: 40.72±9.15, 39.87±2.98, 44.92±10.20, 46.64±4.54, 12 weeks: 51.75±3.28, 57.49±4.11, 58.86±5.58, 54.99±5.99). The results from histomorphometric analysis did not show statistically significant difference.Within the limitation of this study, all experimental groups showed a greater RTV than control group. From histomorphometric analysis, 100 nm experimental group displayed the highest BIC value of all other experimental group and control group and BV value was highest in 100 nm experimental group sacrificed at 4 weeks and 70 nm experimental group sacrificed at 12 weeks. There is also a tendency of increased RTV, BIC and BV values in 12 week group compared to corresponding 4 week group.
Full Text
https://ymlib.yonsei.ac.kr/catalog/search/book-detail/?cid=CAT000000129833
Files in This Item:
제한공개 원문입니다.
Appears in Collections:
2. College of Dentistry (치과대학) > Others (기타) > 3. Dissertation
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/136394
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links