317 448

Cited 0 times in

Evaluation of different self ligationg brackets in leveling vertically displaced canine using 3D FEA

Other Titles
 수직 변위된 견치의 초기 배열에서 다양한 자가 결찰 브라켓을 사용시 나타나는 응력 분포에 대한 유한 요소 분석 
Authors
 권윤희 
Issue Date
2012
Description
Dept. of Dentistry/박사
Abstract
In this study, self-ligation brackets of active and passive type were bonded to canines which were vertically displaced at 1.0 mm, 2.0 mm and 3.0 mm superior to occlusal plane respectively, and metal bracket was bonded as control group. When initial orthodontic force was applied, stress at the tooth and its surrounding alveolar bone were observed from lateral, longitudinal and vertical direction. This study is to investigate on the differences of the stress distribution according to the type of self-ligation brackets and the differences from the metal bracket as the control group by comparing them using finite element analysis. At 1.0 mm above the occlusal plane, vertical stress was the largest in smart clip bracket, and then clippy-c bracket and metal bracket in order, and vertical displacement was the largest in smart clip bracket and the smallest in metal bracket proportionally to the stress. At 2.0 mm above the occlusal plane, vertical stress was the largest in clippy-c bracket, and then smart clip bracket and metal bracket in order, and vertical displacement showed the value proportional to the stress just as in the 1.0mm case. At 1.0 mm and 2.0 mm above the occlusal plane, self-ligation bracket was more advantageous than metal bracket because the vertical stress and vertical displacement of self-ligation bracket was large. At 3.0 mm above the occlusal plane, vertical stress was the largest in smart clip bracket, and then metal bracket and clippy-c bracket in order, and vertical displacement was the largest in smart clip and the smallest in clippy-c bracket proportionally to the vertical stress. At 3.0 mm above the occlusal plane, self-ligation bracket was not always more advantageous because the vertical displacement of clippy-c bracket was the smallest at 3.0 mm superior point. The size of vertical stress and vertical displacement were proportional to each other, and it was that more vertical movement was not always gained in self-ligation bracket and was depending on bracket system.
Files in This Item:
T012400.pdf Download
Appears in Collections:
2. College of Dentistry (치과대학) > Others (기타) > 3. Dissertation
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/134158
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links