역동적 대뇌 관류 CT의 대뇌 관류 지도 구현과 정량 분석을 위한 PC 기반의 소프트웨어 개발

DC Field Value Language
dc.contributor.author허용민-
dc.contributor.author이영한-
dc.date.accessioned2015-08-26T16:42:25Z-
dc.date.available2015-08-26T16:42:25Z-
dc.date.issued2005-
dc.identifier.issn1738-2637-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/114943-
dc.description.abstractPurpose: The purpose of this study was to develop PC-based perfusion software using Microsoft Windows. This software was developed to reformat perfusion maps including CBV (Cerebral Blood Volume), MTT (Mean Transit Time), and CBF (Cerebral Blood Flow) maps and to analyze perfusion quantitatively. Materials and Methods: Windows-based perfusion software was developed using IDL (Interactive Data Language) as the development tool. The perfusion software was written to load the source image from dynamic first-pass cerebral perfusion CT and to reformat perfusion maps. Mean perfusion values in gray matter and white matter were calculated and compared to previously calculated data reported in literature. Results: This software reformatted first pass perfusion maps in a user-friendly PC and calculated CBV, MTT, and CBF values. The values were within the normal range of the mean values when compared to previous studies. Conclusion: CT perfusion maps and perfusion values can be obtained by using the newly developed PC-based perfusion software. Further study is needed to achieve more precise values. However, we believe that in the future, this program may be used in various clinical settings.-
dc.description.statementOfResponsibilityopen-
dc.format.extent79~84-
dc.languageKorean-
dc.publisher대한영상의학회-
dc.relation.isPartOfJournal of the Korean Society of Radiology-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHComputers-
dc.subject.MESHBrain, CT-
dc.subject.MESHBrain, perfusion-
dc.subject.MESHBlood, flow-
dc.title역동적 대뇌 관류 CT의 대뇌 관류 지도 구현과 정량 분석을 위한 PC 기반의 소프트웨어 개발-
dc.title.alternativeDevelopment of PC-based Software to Analyze Dynamic Cerebral Perfusion CT Quantitatively and to Reformat Perfusion Maps-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학)-
dc.contributor.googleauthor이영한-
dc.contributor.googleauthor권우철-
dc.contributor.googleauthor김명순-
dc.contributor.googleauthor허용민-
dc.contributor.googleauthor이명섭-
dc.identifier.doiOAK-2005-02188-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA04359-
dc.contributor.localIdA02967-
dc.relation.journalcodeJ01843-
dc.identifier.eissn2288-2928-
dc.subject.keywordComputers-
dc.subject.keywordBrain, CT-
dc.subject.keywordBrain, perfusion-
dc.subject.keywordBlood, flow-
dc.contributor.alternativeNameHuh, Yong Min-
dc.contributor.alternativeNameLee, Young Han-
dc.contributor.affiliatedAuthorHuh, Yong Min-
dc.contributor.affiliatedAuthorLee, Young Han-
dc.rights.accessRightsfree-
dc.citation.volume53-
dc.citation.number2-
dc.citation.startPage79-
dc.citation.endPage84-
dc.identifier.bibliographicCitationJournal of the Korean Society of Radiology, Vol.53(2) : 79-84, 2005-
dc.identifier.rimsid39328-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.