Finite element mothod ; periodontal ligament ; premolar ; pulp
Keywords
Finite element mothod ; periodontal ligament ; premolar ; pulp
Abstract
In this study, two dimensional and three dimensional finite element models of lower first premolar were analyzed. The mandibular specimen including a premolar was obtained from a cadaver and scanned with micro-CT. Finite element method models were reconstructed from CT images at mid-sagittal plane of the tooth. Most studies have used a wide range of value(0.07${\~}$1000MPa) for elastic modulus of periodontal ligament. The elastic modulus of the periodontal ligament was analyzed by finite element method and compared with that of experiment model. This study indicated that the model without pulp was more suitable than that with pulp in two dimensional finite element analysis.