225 501

Cited 16 times in

Overlapping Ablation Using a Coaxial Radiofrequency Electrode and Multiple Cannulae System: Experimental Study in ex-Vivo Bovine Liver

DC Field Value Language
dc.contributor.author김응엽-
dc.date.accessioned2015-07-15T17:10:37Z-
dc.date.available2015-07-15T17:10:37Z-
dc.date.issued2003-
dc.identifier.issn1229-6929-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/114382-
dc.description.abstractObjective To assess the sizes and configurations of thermal zones after overlapping ablations using a coaxial radiofrequency (RF) electrode and multiple cannulae in ex-vivo bovine liver. Materials and Methods For ablation procedures, a coaxial RF electrode and introducer set was used. Employing real-time ultrasound guidance and overlapping techniques in explanted, fresh bovine liver, we created five kinds of thermal zones with one (n=10), two (n=8), four (n=3), and six ablation spheres (n=3). Following ablation, MR images were obtained and the dimensions of all thermal zones were measured on the longitudinal or transverse section of specimens. The shape of the composite ablation zones was evaluated using three-dimensional MR image reconstruction. Results At gross pathologic examination of ten single-ablation zones (spheres), the long-axis (transverse) and short-axis lengths of zones ranged from 3.7 to 4.4 (mean, 4.1) cm and from 3.5 to 4.0 (mean, 3.7) cm, respectively. The long-axis (transverse) and short-axis lengths of double-ablation zones (cylinders) with 23% overlap ranged from 7.0 to 7.7 (mean, 7.3) cm and from 3.0 to 3.9 (mean, 3.5) cm, respectively; those with 58% overlap ranged from 6.0 to 6.4 (mean, 6.2) cm and from 3.8 to 4.6 (mean, 4.3) cm, respectively. The long-axis (diagonal) and short-axis lengths on a transverse section of four-ablation zones (cakes) ranged from 8.5 to 9.7 (mean, 9.1) cm and from 3.0 to 4.1 (mean, 3.7) cm, respectively. Gross pathologic examination of three composite six-ablation zones (spheres) showed that the long-axis (diagonal) and short-axis lengths of zones ranged from 9.0 to 9.9 (mean, 9.4) cm and from 6.8 to 7.5 (mean, 7.2) cm, respectively. T2-weighted MR images depicted low-signal thermal zones containing multiple curvilinear and spotty regions of hyperintensity. Conclusion Using a coaxial RF electrode and multiple cannulae, together with ultrasound guidance and precise overlapping ablation techniques, we successfully created predictable thermal zones in ex-vivo bovine liver.-
dc.description.statementOfResponsibilityopen-
dc.format.extent117~123-
dc.relation.isPartOfKOREAN JOURNAL OF RADIOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAnimals-
dc.subject.MESHCatheter Ablation/methods*-
dc.subject.MESHCattle-
dc.subject.MESHLiver/pathology-
dc.subject.MESHLiver/surgery*-
dc.subject.MESHMagnetic Resonance Imaging-
dc.titleOverlapping Ablation Using a Coaxial Radiofrequency Electrode and Multiple Cannulae System: Experimental Study in ex-Vivo Bovine Liver-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학)-
dc.contributor.googleauthorDongil Choi-
dc.contributor.googleauthorHyo K. Lim-
dc.contributor.googleauthorSeong Hyun Kim-
dc.contributor.googleauthorSooah Kim-
dc.contributor.googleauthorEung Yeop Kim-
dc.contributor.googleauthorSeung Kwon Kim-
dc.contributor.googleauthorJongmee Lee-
dc.contributor.googleauthorMin Ju Kim-
dc.identifier.doi10.3348/kjr.2003.4.2.117-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00832-
dc.relation.journalcodeJ02884-
dc.identifier.eissn2005-8330-
dc.identifier.pmid12845307-
dc.subject.keyword12845307-
dc.contributor.alternativeNameKim, Eung Yeop-
dc.contributor.affiliatedAuthorKim, Eung Yeop-
dc.rights.accessRightsfree-
dc.citation.volume4-
dc.citation.number2-
dc.citation.startPage117-
dc.citation.endPage123-
dc.identifier.bibliographicCitationKOREAN JOURNAL OF RADIOLOGY, Vol.4(2) : 117-123, 2003-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.