Cited 0 times in

전기 치수 검사 시 역치 자극 이후 과용 자극 시간의 측정

DC Field Value Language
dc.contributor.author김덕원-
dc.contributor.author김수찬-
dc.contributor.author남기창-
dc.contributor.author안선희-
dc.contributor.author이승종-
dc.date.accessioned2015-07-14T17:07:17Z-
dc.date.available2015-07-14T17:07:17Z-
dc.date.issued2004-
dc.identifier.issn1225-0864-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/112249-
dc.description.abstractUse of electric pulp testing elicits painful response in vital teeth. In this study, we examined the excessive time from pain feeling to stimulation disconnection in clinical situation. D626D (Parkell Inc., USA.) scan type electric pulp tester was used in total of 23 young healthy individuals. Each of the right central incisors and first premolars were used as testing teeth. Stimulation disconnection was achieved by EMG in anterior belly of digastric muscle, finger span, and voice and the excessive stimulation time over the sensory threshold was recorded. As a result, we found that the short responses before the stimulation disconnection appeared following order; EMG, finger span, and voice. The EMG disconnection is suggested to be used to reduce the excessive stimulus time in electric pulp testing.-
dc.description.statementOfResponsibilityopen-
dc.format.extent226~232-
dc.relation.isPartOfJournal of Korean Academy of Operative Dentistry (대한치과보존학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title전기 치수 검사 시 역치 자극 이후 과용 자극 시간의 측정-
dc.title.alternativeMeasurement of the excessive stimulus time after the sensory threshold level during electric pulp testing-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Conservative Dentistry (보존과학)-
dc.contributor.googleauthor남기창-
dc.contributor.googleauthor안선희-
dc.contributor.googleauthor이승종-
dc.contributor.googleauthor김덕원-
dc.contributor.googleauthor김수찬-
dc.identifier.doi10.5395/JKACD.2004.29.3.226-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.relation.journalcodeJ01488-
dc.subject.keywordTooth-
dc.subject.keywordPulp test-
dc.subject.keywordElectric pulp tester-
dc.subject.keywordPulp vitality-
dc.subject.keywordPain response-
dc.subject.keywordEMG (electromyograph)-
dc.subject.keywordStimulation time-
dc.contributor.alternativeNameKim, Deok Won-
dc.contributor.alternativeNameKim, Soo Chan-
dc.contributor.alternativeNameNam, Ki Chang-
dc.contributor.alternativeNameAhn, Seon Hui-
dc.contributor.alternativeNameLee, Seung Jong-
dc.rights.accessRightsfree-
dc.citation.volume29-
dc.citation.number3-
dc.citation.startPage226-
dc.citation.endPage232-
dc.identifier.bibliographicCitationJournal of Korean Academy of Operative Dentistry (대한치과보존학회지), Vol.29(3) : 226-232, 2004-
dc.identifier.rimsid37999-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Medical Engineering (의학공학교실) > 1. Journal Papers
2. College of Dentistry (치과대학) > Dept. of Conservative Dentistry (보존과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.