597 572

Cited 0 times in

면역혈청검사 신빙도 조사 결과보고 (2003)

Other Titles
 Annual Report on External Quality Assessment in Immunoserology in Korea (2003) 
Authors
 차영주  ;  권소영  ;  금동길  ;  김성원  ;  김신규  ;  김재룡  ;  김현숙  ;  박명희  ;  박성훈  ;  박애자  ;  손한철  ;  양주석  ;  이계숙  ;  채석래 
Citation
 Journal of Laboratory Medicine and Quality Assurance (임상검사와 정도관리), Vol.26(1) : 47-69, 2004 
Journal Title
Journal of Laboratory Medicine and Quality Assurance(임상검사와 정도관리)
ISSN
 1225-097X 
Issue Date
2004
Keywords
Immunoserology ; External quality assessment ; HBsAg ; Anti-HBs ; Anti-HCV ; AntiHIV ; CRP ; RF ; ASO ; Widal ; STS ; ICA ; CIA ; EIA ; MEIA ; Nephelometry ; TIA
Abstract
The followings are the results for external quality assessment (EQA) in immunoserology for 2003: 1. Evaluation of EQA was done in 2 trials in May and November, about 99% of laboratories participating average 8.2 items. 2. In C-reactive protein (CRP), rheumatoid factor (RF) and anti-streptolysin O (ASO) tests, about 63%, 49% and 44% of the participating laboratories respectively have used quantitative assays. Because the laboratories using quanitiative assays were on the increase annually, commercial control, LiquicheckTM Immunology Contol from Bio-Rad Laboratories (Irvine, CA, USA) was used to assure the quality of quantitiavie results in 2003. A few laboratories reproted the outlier results, comparing with the reference ranges presented by the company. 3. Over 92% of participating laboratoreis have used imunoassays including enzyme immunoassay (EIA), microparticle EIA (MEIA), chemiluminescence immunoassay (CIA), immunochromatography assay (ICA) or radioimmunoassay (RIA) for detedting viral antigens or antibodies. Especially for anti-HCV, over 98% of participating laboratoreis have used various kind of imunoassays. Laboratories using ICA increased and about 24% of participating laboratoreis have used ICA for anti-HCV and anti-HIV. However, many laboratories using ICA for detecting anti-HCV reported false negative results, suggesting lower sensitivity of ICA than those of other immunoassays. 4. The criteria of interpretation were considered to be evaluated in Widal test and laboratories using ICA increased in serological tests for syphilis.
Files in This Item:
T200400198.pdf Download
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Hyon Suk(김현숙) ORCID logo https://orcid.org/0000-0001-5662-7740
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/111955
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links