1 549

Cited 0 times in

정 전류원을 이용한 치수(齒髓) 검사기의 개발

DC Field Value Language
dc.contributor.author김덕원-
dc.contributor.author김수찬-
dc.contributor.author김재성-
dc.contributor.author남기창-
dc.contributor.author이승종-
dc.date.accessioned2015-07-14T16:43:56Z-
dc.date.available2015-07-14T16:43:56Z-
dc.date.issued2004-
dc.identifier.issn2287-5026-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/111477-
dc.description.abstractElectric stimulation of teeth has been used for assessing pulp vitality. The principle is based upon the assumption that a subject feels the pain produced by electrical current stimulation of intradental nerve. Because of very high and wide range of impedance of the enamel, it is very difficult to determine stimulation levels regardless of teeth status. Most pulp testers adopt voltage stimulation method and thus, their stimulating threshold levels significantly depend on each individual. Therefore, a constant current stimulator is necessary to minimize the effect of wide variation due to different enamel thickness. And it is also necessary to test teeth vitality with a wide current range regardless of tooth impedance. In this study, we constructed a burst-wave type pulp tester to reduce the pain using a current stabilizing circuit with the maximum current of 150 uA.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOf전자공학회논문지.SC (System and Control)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title정 전류원을 이용한 치수(齒髓) 검사기의 개발-
dc.title.alternativeDevelopment of an Electric Pulp Tester with Constant Current Source-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Medical Engineering (의학공학)-
dc.contributor.googleauthor김재성-
dc.contributor.googleauthor남기창-
dc.contributor.googleauthor김덕원-
dc.contributor.googleauthor이승종-
dc.contributor.googleauthor김수찬-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.relation.journalcodeJ02833-
dc.identifier.urlhttps://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE00505066-
dc.subject.keywordelectric pulp test-
dc.subject.keywordpulp vitality-
dc.subject.keywordconstant current-
dc.subject.keywordburst wave-
dc.contributor.alternativeNameKim, Deok Won-
dc.contributor.alternativeNameKim, Soo Chan-
dc.contributor.alternativeNameKim, Jae Sung-
dc.contributor.alternativeNameNam, Ki Chang-
dc.contributor.alternativeNameLee, Seung Jong-
dc.rights.accessRightsnot free-
dc.citation.volume41-
dc.citation.number2-
dc.citation.startPage123-
dc.citation.endPage130-
dc.identifier.bibliographicCitation전자공학회논문지.SC (System and Control), Vol.41(2) : 123-130, 2004-
dc.identifier.rimsid34860-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Medical Engineering (의학공학교실) > 1. Journal Papers
2. College of Dentistry (치과대학) > Dept. of Conservative Dentistry (보존과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.