Cited 49 times in
Problems Encountered during and after Stent-Graft Treatment of Aortic Dissection
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 고흥규 | - |
dc.contributor.author | 서상현 | - |
dc.contributor.author | 원정윤 | - |
dc.contributor.author | 이광훈 | - |
dc.contributor.author | 이도연 | - |
dc.contributor.author | 장병철 | - |
dc.contributor.author | 최동훈 | - |
dc.contributor.author | 원종윤 | - |
dc.date.accessioned | 2015-06-10T13:05:22Z | - |
dc.date.available | 2015-06-10T13:05:22Z | - |
dc.date.issued | 2006 | - |
dc.identifier.issn | 1051-0443 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/110987 | - |
dc.description.abstract | PURPOSE: The authors report their experiences with the problems encountered during and after stent-graft placement in patients with aortic dissections. MATERIALS AND METHODS: Between July 1994 and December 2003, stent-graft placement was performed in 60 patients with aortic dissections, 9 patients with Stanford type A dissection and 51 patients with type B. Ten patients had acute dissection and 50 patients had chronic dissection. Each patient was followed for 12 to 107 months (mean, 33 mo). All cases were retrospectively reviewed for any problem that occurred during and after the procedure. RESULTS: During the procedure, there were two cases (3%) of stent-graft migration, one case (2%) of stent-graft torsion, two cases (3%) of stent-graft folding due to oversizing, three cases (5%) of persistent thoracic false lumen flow by the appearance of a hidden intimal tear, one case (2%) of new intimal tear that resulted in retrograde type A dissection, and 12 cases (20%) of type I endoleaks on aortograms taken immediately after the procedure. During the follow-up period, one case (2%) of transient cerebral ischemia, six cases (10%) of persistent type I endoleaks, two cases (3%) of type II endoleaks through the intercostal artery, four cases (7%) with progressive dilatation of abdominal false lumen, six cases (10%) of new intimal tears which resulted in saccular aneurysms (n=4) or new dissections (n=2) on either or both ends of the stent-graft, and two cases (3%) of mechanical failure were observed. Overall, five patients (8%) required surgical conversion, and there were no cases of procedure-related mortality. CONCLUSION: Various problems can occur during and after stent-graft placement in aortic dissection. The thorough evaluation of preoperative imaging and close follow-up are mandatory to optimize the management of such problems. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 271~281 | - |
dc.relation.isPartOf | JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Aged, 80 and over | - |
dc.subject.MESH | Aneurysm, Dissecting/diagnostic imaging | - |
dc.subject.MESH | Aneurysm, Dissecting/surgery* | - |
dc.subject.MESH | Aortography | - |
dc.subject.MESH | Blood Vessel Prosthesis Implantation/methods* | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Intraoperative Complications/epidemiology* | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Polytetrafluoroethylene | - |
dc.subject.MESH | Postoperative Complications/epidemiology* | - |
dc.subject.MESH | Retrospective Studies | - |
dc.subject.MESH | Stents* | - |
dc.subject.MESH | Tomography, X-Ray Computed | - |
dc.subject.MESH | Treatment Outcome | - |
dc.title | Problems Encountered during and after Stent-Graft Treatment of Aortic Dissection | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Radiology (영상의학) | - |
dc.contributor.googleauthor | Jong Yun Won | - |
dc.contributor.googleauthor | Sang-Hyun Suh | - |
dc.contributor.googleauthor | Heung-kyu Ko | - |
dc.contributor.googleauthor | Kwang Hoon Lee | - |
dc.contributor.googleauthor | Won Heum Shim | - |
dc.contributor.googleauthor | Byung-Chul Chang | - |
dc.contributor.googleauthor | Dong Hoon Choi | - |
dc.contributor.googleauthor | Sang Joon Park | - |
dc.contributor.googleauthor | Do Yun Lee | - |
dc.identifier.doi | 10.1097/01.RVI.0000195141.98163.30 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00157 | - |
dc.contributor.localId | A01886 | - |
dc.contributor.localId | A02676 | - |
dc.contributor.localId | A02718 | - |
dc.contributor.localId | A03430 | - |
dc.contributor.localId | A04053 | - |
dc.contributor.localId | A02443 | - |
dc.relation.journalcode | J01922 | - |
dc.identifier.eissn | 1535-7732 | - |
dc.identifier.pmid | 16517772 | - |
dc.identifier.url | http://www.sciencedirect.com/science/article/pii/S105104430760030X | - |
dc.contributor.alternativeName | Ko, Heung Kyu | - |
dc.contributor.alternativeName | Suh, Sang Hyun | - |
dc.contributor.alternativeName | Won, Jong Yun | - |
dc.contributor.alternativeName | Lee, Kwang Hun | - |
dc.contributor.alternativeName | Lee, Do Yun | - |
dc.contributor.alternativeName | Chang, Byung Chul | - |
dc.contributor.alternativeName | Choi, Dong Hoon | - |
dc.contributor.affiliatedAuthor | Ko, Heung Kyu | - |
dc.contributor.affiliatedAuthor | Suh, Sang Hyun | - |
dc.contributor.affiliatedAuthor | Lee, Kwang Hun | - |
dc.contributor.affiliatedAuthor | Lee, Do Yun | - |
dc.contributor.affiliatedAuthor | Chang, Byung Chul | - |
dc.contributor.affiliatedAuthor | Choi, Dong Hoon | - |
dc.contributor.affiliatedAuthor | Won, Jong Yun | - |
dc.rights.accessRights | not free | - |
dc.citation.volume | 17 | - |
dc.citation.number | 2 Pt 1 | - |
dc.citation.startPage | 271 | - |
dc.citation.endPage | 281 | - |
dc.identifier.bibliographicCitation | JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, Vol.17(2 Pt 1) : 271-281, 2006 | - |
dc.identifier.rimsid | 51902 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.