337 582

Cited 26 times in

Anterior chamber measurements by pentacam and AS-OCT in eyes with normal open angles.

Authors
 Jeong-Ho Yi  ;  Hun Lee  ;  Samin Hong  ;  Gong Je Seong  ;  Sung Yong Kang  ;  Kyoung Tak Ma  ;  Chan Yun Kim 
Citation
 Korean Journal of Ophthalmology, Vol.22(4) : 242-245, 2008 
Journal Title
Korean Journal of Ophthalmology
ISSN
 1011-8942 
Issue Date
2008
MeSH
Adolescent ; Adult ; Anterior Chamber/anatomy & histology* ; Anterior Eye Segment ; Cross-Sectional Studies ; Diagnostic Techniques, Ophthalmological* ; Female ; Humans ; Male ; Observer Variation ; Photography/methods* ; Prospective Studies ; Reproducibility of Results ; Tomography, Optical Coherence/methods* ; Trabecular Meshwork/anatomy & histology ; Young Adult
Keywords
Anterior chamber angle ; Anterior chamber depth ; Anterior segment optical coherence tomogaphy ; pentacam
Abstract
PURPOSE: To assess the reproducibility and agreement of anterior chamber measurements between the Pentacam (PTC) and the Anterior segment optical coherence tomography (AOCT) in normal healthy eyes with open angle.

METHODS: Prospective cross-sectional comparative case series. A total of 162 eyes of 81 healthy volunteers with normal open angle were included in this study. Anterior chamber angle (ACA) and anterior chamber depth (ACD) were measured with PTC and AOCT. Intra-observer variability and inter-methods agreement of both instruments for ACA and ACD were evaluated.

RESULTS: Values of temporal and nasal ACA measured by two instruments were similar, and the results of ACD were also not significantly different between modalities (p > 0.01). ACA and ACD measurements by PTC and AOCT showed good intra-observer and inter-method agreements (all > 0.9).

CONCLUSIONS: PTC and AOCT are presumed to be very useful for the anterior chamber angle examination. They may provide good images and quantitative data about the angle structures including ACA and ACD
Files in This Item:
T200805210.pdf Download
DOI
10.3341/kjo.2008.22.4.242
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers
Yonsei Authors
Kang, Sung Yong(강성용)
Kim, Chan Yun(김찬윤) ORCID logo https://orcid.org/0000-0002-8373-9999
Seong, Gong Je(성공제) ORCID logo https://orcid.org/0000-0002-5456-4296
Hong, Sa Min(홍사민)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/108348
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links